... ... @@ -328,7 +328,7 @@
328 328  * Other contactors are open;
329 329  * There is an error from the the "Errors 1, 2 ..." bitfileds.
330 330  
331 -In “Automatic” mode, the main contactor closes by internal charging and discharging algorithms at the same time with ther contactors.
331 +In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors.
332 332  
333 333  In “On demand” mode, the main contactor closes by external the “Close Main contactor” request.
334 334  
... ... @@ -431,24 +431,8 @@
431 431  * On charger connected – charging is allowed when there is a signal “Charger connected”;
432 432  * On charge request – charging is allowed when there is a signal “Charge request”.
433 433  
434 -If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors appears:
434 +If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals:
435 435  
436 -* Overvoltage;
437 -* Overcurrent;
438 -* High temperature (CH);
439 -* Low temperature (CH);
440 -* HYG offline (optional);
441 -* Combilift offline (optional);
442 -* Spirit offline (optional);
443 -* Spirit charger error (optional);
444 -* Short circuit (optional);
445 -* High contactor temperature (optional);
446 -* CH contactor cycles error;
447 -* Precharge error (optional);
448 -* Critical error
449 -
450 -or one of the signals:
451 -
452 452  * Service reset;
453 453  * Power down request;
454 454  * Inhibit charging,
... ... @@ -457,17 +457,17 @@
457 457  
458 458  When the algorithm "**On charger connected**" is selected, the control is performed as follows:
459 459  
460 -* If there is a signal “Charger connected” and there are no errors (see the list above), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;
444 +* If there is a signal “Charger connected” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;
461 461  * If the signal “Charger connected” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens;
462 462  * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed);
463 -* If errors in the list above occur the charging contactor and allow charging contactor open.
447 +* If errors from the "Errors 1, 2 ..." bitfields occur the charging contactor and allow charging contactor open.
464 464  
465 465  When the "**On charge request**" algorithm selected, the control is performed as follows:
466 466  
467 -* If there is a signal “Charge request” and there are no errors (see the list above), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;
451 +* If there is a signal “Charge request” and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the charging contactor and the allow charging contactor close;
468 468  * If the signal “Charge request” disappears, the allow charging contactor opens and after the delay time T,,off,, the charging contactor opens;
469 469  * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed);
470 -* If errors in the list above occur the charging contactor and allow charging contactor open.
454 +* If errors from the "Errors 1, 2 ..." bitfields occur the charging contactor and allow charging contactor open.
471 471  
472 472  (% class="box infomessage" %)
473 473  (((
... ... @@ -504,26 +504,8 @@
504 504  * On charger disconnected – load is connected when there is no signal “Charger connected”;
505 505  * On discharge request – load is connected when there is signal “Discharge request”.
506 506  
507 -When the algorithm "**Always on**" is selected, the discharging contactor is always closed. If at least one of the errors appears:
491 +When the algorithm "**Always on**" is selected, the discharging contactor is always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals:
508 508  
509 -* Undervoltage;
510 -* Overvoltage (optional);
511 -* Overcurrent;
512 -* High temperature (DCH);
513 -* Low temperature (DCH) (optional);
514 -* HYG offline (optional);
515 -* Combilift offline (optional);
516 -* Spirit offline (optional);
517 -* Spirit charger error (optional);
518 -* Short circuit (optional);
519 -* High contactor temperature (optional);
520 -* Unallowable charging;
521 -* DCH contactor cycles error;
522 -* Precharge error (optional);
523 -* Critical error
524 -
525 -or one of the signals:
526 -
527 527  * Service reset
528 528  * Power down request
529 529  * Inhibit discharging
... ... @@ -532,13 +532,13 @@
532 532  
533 533  If the algorithm "**On charger disconnected**" is selected, the control is performed as follows:
534 534  
535 -* if there is no signal “Charger connected”, the charging contactor is open and there are no errors (see the list above), then through the delay time T,,on,, the discharging contactor closes;
536 -* If the signal “Charger connected” appears or errors occur (see the list above), then after the delay time T,,off,, the discharging contactor opens.
501 +* if there is no signal “Charger connected”, the charging contactor is open and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the discharging contactor closes;
502 +* If the signal “Charger connected” appears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the discharging contactor opens.
537 537  
538 538  When the "**On discharge request**" algorithm selected, the control is performed as follows:
539 539  
540 -* if there is signal “Discharge request”, the charging contactor is open and there are no errors (see the list above), then through the delay time T,,on,, the discharging contactor closes;
541 -* If the signal “Discharge request” disappears or errors occur (see the list above), then after the delay time T,,off,, the discharging contactor opens.
506 +* if there is signal “Discharge request”, the charging contactor is open and there are no errors (see the "Errors 1, 2 ..." bitfields), then through the delay time T,,on,, the discharging contactor closes;
507 +* If the signal “Discharge request” disappears or errors occur (see the "Errors 1, 2 ..." bitfields), then after the delay time T,,off,, the discharging contactor opens.
542 542  
543 543  (% class="box infomessage" %)
544 544  (((
... ... @@ -545,7 +545,7 @@
545 545  **Note: **when errors occur in the system, the **Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
546 546  )))
547 547  
548 -The device supports controlling the precharging contactor. The duration of switching on the precharging contactor before closing the discharging (load) contactor is adjusted.
514 +The device supports controlling the precharging contactor (see [[Precharge>>doc:||anchor="HPrecharge"]]).
549 549  
550 550  To change the parameters of the battery discharge control algorithm, select the "Control → Discharge" section:
551 551  
... ... @@ -614,7 +614,7 @@
614 614  
615 615  * the battery has low SOC;
616 616  * the battery voltage is out of range;
617 -* the battery system errors are detected.
583 +* the errors are detected (configured in the "Errors 1, 2 ..." bitfields).
618 618  
619 619  (% class="box infomessage" %)
620 620  (((
... ... @@ -762,7 +762,7 @@
762 762  
763 763  * the minimum temperature among all cells of the battery is greater than the “Tolerant cell temperature” value during the “Delay before stopping the heater” time.
764 764  
765 -If there is the "Heater" signal, the heater contactor closes and/or a signal is output to the corresponding digital output.
731 +If there is the "Heater" signal, the heater contactor closes and/or a signal is set to the corresponding digital output.
766 766  
767 767  === Cooler ===
768 768  
... ... @@ -789,7 +789,7 @@
789 789  
790 790  * the maximum temperature among all cells of the battery is less than the “Tolerant cell temperature” value during the “Delay before stopping the cooler” time.
791 791  
792 -If there is the "Cooler" signal, the cooler contactor closes and/or a signal is output to the corresponding digital output.
758 +If there is the "Cooler" signal, the cooler contactor closes and/or a signal is set to the corresponding digital output.
793 793  
794 794  === High voltage ===
795 795