... ... @@ -1,5 +1,5 @@
1 1  (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 -= Settings =
2 += Configuration =
3 3  
4 4  (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 5  == Control ==
... ... @@ -213,18 +213,18 @@
213 213  * Enable – a flag to start calculation of the charge current limit;
214 214  * Maximum charge current – a maximum allowable value of the charge current (under normal conditions), A;
215 215  * Rate of change – a rate of change the current limit to a new value (0 is for immediate change), A/s;
216 -* Option 1: Limit charge current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current Kcs depending on SOC and battery temperature;
216 +* Option 1: Limit charge current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current** Kcs** depending on SOC and battery temperature;
217 217  * Option 1: SOC x Temperature x Factor – the dependence of the correction factor on SOC and battery temperature;
218 -* Option 2: Limit charge current by the contactor temperature – a flag to enable correction of maximum allowable charging current Kcc depending on contactor temperature;
218 +* Option 2: Limit charge current by the contactor temperature – a flag to enable correction of maximum allowable charging current **Kcc** depending on contactor temperature;
219 219  * Option 2: Contactor temperature x Factor – the dependence of the correction factor on SOC and contactor temperature;
220 -* Option 3: Limit charge current by the maximum cell voltage - a flag to enable correction of maximum allowable charging current Kcv depending on maximum cell voltage;
220 +* Option 3: Limit charge current by the maximum cell voltage - a flag to enable correction of maximum allowable charging current **Kcv** depending on maximum cell voltage;
221 221  * Option 3: Cell voltage x Factor – the dependence of the correction factor on maximum cell voltage;
222 -* Option 4: Limit charge current by the cell temperature - a flag to enable correction of maximum allowable charging current Kct depending on maximum cell temperature;
222 +* Option 4: Limit charge current by the cell temperature - a flag to enable correction of maximum allowable charging current **Kct** depending on maximum cell temperature;
223 223  * Option 4: Cell temperature x Factor – the dependence of the correction factor on maximum cell temperature.
224 224  
225 225  Value of the charge current limit at given SOC, temperature, contactors temperature, maximum cell voltage and maximum cell temperature is calculated as follows:
226 226  
227 -**Charging current limit = Maximum charging current × Kcs × Kcc × Kcv × Kct**
227 +**Charge current limit = Maximum charge current × Kcs × Kcc × Kcv × Kct**
228 228  
229 229  === Discharge map ===
230 230  
... ... @@ -241,18 +241,18 @@
241 241  * Enable – a flag to start calculation of the discharge current limit;
242 242  * Maximum discharge current – a maximum allowable value of the discharge current (under normal conditions), A;
243 243  * Rate of change – a rate of change the current limit to a new value (0 is for immediate change), A/s;
244 -* Option 1: Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current Kds depending on SOC and temperature;
244 +* Option 1: Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current **Kds **depending on SOC and temperature;
245 245  * Option 1: SOC x Temperature x Factor – the dependence of the correction factor on SOC and battery temperature;
246 -* Option 2: Limit discharge current by the contactor temperature – a flag to enable correction of maximum allowable discharging current Kdc depending on contactor temperature;
246 +* Option 2: Limit discharge current by the contactor temperature – a flag to enable correction of maximum allowable discharging current **Kdc** depending on contactor temperature;
247 247  * Option 2: Contactor temperature x Factor – the dependence of the correction factor on SOC and contactor temperature;
248 -* Option 3: Limit discharge current by the cell voltage - a flag to enable correction of maximum allowable discharging current Kdv depending on minimum cell voltage;
248 +* Option 3: Limit discharge current by the cell voltage - a flag to enable correction of maximum allowable discharging current **Kdv** depending on minimum cell voltage;
249 249  * Option 3: Cell voltage x Factor – the dependence of the correction factor on minimum cell voltage;
250 -* Option 4: Limit discharge current by the cell temperature - a flag to enable correction of maximum allowable discharging current Kdt depending on maximum cell temperature;
250 +* Option 4: Limit discharge current by the cell temperature - a flag to enable correction of maximum allowable discharging current **Kdt** depending on maximum cell temperature;
251 251  * Option 4: Cell voltage x Factor – the dependence of the correction factor on minimum cell temperature.
252 252  
253 253  Value of the discharge current limit at given SOC, temperature, contactors temperature, minimum cell voltage and maximum cell temperature is calculated as follows:
254 254  
255 -**Discharging current limit = Maximum discharging current × Kds × Kdc × Kdv × Kdt**
255 +**Discharge current limit = Maximum discharge current × Kds × Kdc × Kdv × Kdt**
256 256  
257 257  === Charge map (PEAK & CONTINUOUS) ===
258 258  
... ... @@ -320,31 +320,15 @@
320 320  
321 321  In “Always on” mode main contactor closes if all the following is true:
322 322  
323 -* Charging contactor is open;
324 -* Discharging contactor is open;
325 -* There are no errors from the list below:
326 -** Overcurrent;
327 -** Undervoltage;
328 -** Overvoltage;
329 -** High temperature (CH);
330 -** High temperature (DCH);
331 -** Unallowable charging;
332 -** Critical error.
323 +* Other contactors are open;
324 +* There are no errors from the "Errors 1, 2 ..." bitfileds.
333 333  
334 334  In “Always on” mode main contactor opens if all the following is true:
335 335  
336 -* Charging contactor is open;
337 -* Discharging contactor is open;
338 -* There is an error from the list below:
339 -** Overcurrent;
340 -** Undervoltage;
341 -** Overvoltage;
342 -** High temperature (CH);
343 -** High temperature (DCH);
344 -** Unallowable charging;
345 -** Critical error.
328 +* Other contactors are open;
329 +* There is an error from the the "Errors 1, 2 ..." bitfileds.
346 346  
347 -In “Automatic” mode, the main contactor closes by internal charging and discharging algorithms at the same time with Precharging, Charging and Discharging contactors.
331 +In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors.
348 348  
349 349  In “On demand” mode, the main contactor closes by external the “Close Main contactor” request.
350 350  
... ... @@ -447,29 +447,13 @@
447 447  * On charger connected – charging is allowed when there is a signal “Charger connected”;
448 448  * On charge request – charging is allowed when there is a signal “Charge request”.
449 449  
450 -If the "**Always on**" algorithm is selected, the charging contactor and the allow charging contactor are always closed. If at least one of the errors appears:
434 +If the "**Always on**" algorithm is selected, the charging contactor is always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfields appears or one of the signals:
451 451  
452 -* Overvoltage;
453 -* Overcurrent;
454 -* High temperature (CH);
455 -* Low temperature (CH);
456 -* HYG offline (optional);
457 -* Combilift offline (optional);
458 -* Spirit offline (optional);
459 -* Spirit charger error (optional);
460 -* Short circuit (optional);
461 -* High contactor temperature (optional);
462 -* CH contactor cycles error;
463 -* Precharge error (optional);
464 -* Critical error
465 -
466 -or one of the signals:
467 -
468 468  * Service reset;
469 469  * Power down request;
470 470  * Inhibit charging,
471 471  
472 -both contactors are open (no current flows).
440 +contactor opens (no current flows).
473 473  
474 474  When the algorithm "**On charger connected**" is selected, the control is performed as follows:
475 475