Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Settings=2 += Configuration = 3 3 4 4 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == Control == ... ... @@ -213,18 +213,18 @@ 213 213 * Enable – a flag to start calculation of the charge current limit; 214 214 * Maximum charge current – a maximum allowable value of the charge current (under normal conditions), A; 215 215 * Rate of change – a rate of change the current limit to a new value (0 is for immediate change), A/s; 216 -* Option 1: Limit charge current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current 216 +* Option 1: Limit charge current by the battery SOC and temperature – a flag to enable correction of maximum allowable charging current** Kcs** depending on SOC and battery temperature; 217 217 * Option 1: SOC x Temperature x Factor – the dependence of the correction factor on SOC and battery temperature; 218 -* Option 2: Limit charge current by the contactor temperature – a flag to enable correction of maximum allowable charging current Kcc depending on contactor temperature; 218 +* Option 2: Limit charge current by the contactor temperature – a flag to enable correction of maximum allowable charging current **Kcc** depending on contactor temperature; 219 219 * Option 2: Contactor temperature x Factor – the dependence of the correction factor on SOC and contactor temperature; 220 -* Option 3: Limit charge current by the maximum cell voltage - a flag to enable correction of maximum allowable charging current Kcv depending on maximum cell voltage; 220 +* Option 3: Limit charge current by the maximum cell voltage - a flag to enable correction of maximum allowable charging current **Kcv** depending on maximum cell voltage; 221 221 * Option 3: Cell voltage x Factor – the dependence of the correction factor on maximum cell voltage; 222 -* Option 4: Limit charge current by the cell temperature - a flag to enable correction of maximum allowable charging current Kct depending on maximum cell temperature; 222 +* Option 4: Limit charge current by the cell temperature - a flag to enable correction of maximum allowable charging current **Kct** depending on maximum cell temperature; 223 223 * Option 4: Cell temperature x Factor – the dependence of the correction factor on maximum cell temperature. 224 224 225 225 Value of the charge current limit at given SOC, temperature, contactors temperature, maximum cell voltage and maximum cell temperature is calculated as follows: 226 226 227 -**Charg ingcurrent limit = Maximum chargingcurrent × Kcs × Kcc × Kcv × Kct**227 +**Charge current limit = Maximum charge current × Kcs × Kcc × Kcv × Kct** 228 228 229 229 === Discharge map === 230 230 ... ... @@ -241,18 +241,18 @@ 241 241 * Enable – a flag to start calculation of the discharge current limit; 242 242 * Maximum discharge current – a maximum allowable value of the discharge current (under normal conditions), A; 243 243 * Rate of change – a rate of change the current limit to a new value (0 is for immediate change), A/s; 244 -* Option 1: Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current Kds depending on SOC and temperature; 244 +* Option 1: Limit discharging current by the battery SOC and temperature – a flag to enable correction of maximum allowable discharging current **Kds **depending on SOC and temperature; 245 245 * Option 1: SOC x Temperature x Factor – the dependence of the correction factor on SOC and battery temperature; 246 -* Option 2: Limit discharge current by the contactor temperature – a flag to enable correction of maximum allowable discharging current Kdc depending on contactor temperature; 246 +* Option 2: Limit discharge current by the contactor temperature – a flag to enable correction of maximum allowable discharging current **Kdc** depending on contactor temperature; 247 247 * Option 2: Contactor temperature x Factor – the dependence of the correction factor on SOC and contactor temperature; 248 -* Option 3: Limit discharge current by the cell voltage - a flag to enable correction of maximum allowable discharging current Kdv depending on minimum cell voltage; 248 +* Option 3: Limit discharge current by the cell voltage - a flag to enable correction of maximum allowable discharging current **Kdv** depending on minimum cell voltage; 249 249 * Option 3: Cell voltage x Factor – the dependence of the correction factor on minimum cell voltage; 250 -* Option 4: Limit discharge current by the cell temperature - a flag to enable correction of maximum allowable discharging current Kdt depending on maximum cell temperature; 250 +* Option 4: Limit discharge current by the cell temperature - a flag to enable correction of maximum allowable discharging current **Kdt** depending on maximum cell temperature; 251 251 * Option 4: Cell voltage x Factor – the dependence of the correction factor on minimum cell temperature. 252 252 253 253 Value of the discharge current limit at given SOC, temperature, contactors temperature, minimum cell voltage and maximum cell temperature is calculated as follows: 254 254 255 -**Discharg ingcurrent limit = Maximum dischargingcurrent × Kds × Kdc × Kdv × Kdt**255 +**Discharge current limit = Maximum discharge current × Kds × Kdc × Kdv × Kdt** 256 256 257 257 === Charge map (PEAK & CONTINUOUS) === 258 258 ... ... @@ -320,31 +320,15 @@ 320 320 321 321 In “Always on” mode main contactor closes if all the following is true: 322 322 323 -* Charging contactor is open; 324 -* Discharging contactor is open; 325 -* There are no errors from the list below: 326 -** Overcurrent; 327 -** Undervoltage; 328 -** Overvoltage; 329 -** High temperature (CH); 330 -** High temperature (DCH); 331 -** Unallowable charging; 332 -** Critical error. 323 +* Other contactors are open; 324 +* There are no errors from the "Errors 1, 2 ..." bitfileds. 333 333 334 334 In “Always on” mode main contactor opens if all the following is true: 335 335 336 -* Charging contactor is open; 337 -* Discharging contactor is open; 338 -* There is an error from the list below: 339 -** Overcurrent; 340 -** Undervoltage; 341 -** Overvoltage; 342 -** High temperature (CH); 343 -** High temperature (DCH); 344 -** Unallowable charging; 345 -** Critical error. 328 +* Other contactors are open; 329 +* There is an error from the the "Errors 1, 2 ..." bitfileds. 346 346 347 -In “Automatic” mode, the main contactor closes by internal charging and discharging algorithms at the same time withPrecharging,Charging and Discharging contactors.331 +In “Automatic” mode, the main contactor closes by internal algorithms at the same time with other contactors. 348 348 349 349 In “On demand” mode, the main contactor closes by external the “Close Main contactor” request. 350 350 ... ... @@ -447,29 +447,13 @@ 447 447 * On charger connected – charging is allowed when there is a signal “Charger connected”; 448 448 * On charge request – charging is allowed when there is a signal “Charge request”. 449 449 450 -If the "**Always on**" algorithm is selected, the charging contactor and the allow chargingcontactor are always closed. If at least one of the errors appears:434 +If the "**Always on**" algorithm is selected, the charging contactor is always closed. If at least one of the errors from the "Errors 1, 2 ..." bitfield appears or one of the signals: 451 451 452 -* Overvoltage; 453 -* Overcurrent; 454 -* High temperature (CH); 455 -* Low temperature (CH); 456 -* HYG offline (optional); 457 -* Combilift offline (optional); 458 -* Spirit offline (optional); 459 -* Spirit charger error (optional); 460 -* Short circuit (optional); 461 -* High contactor temperature (optional); 462 -* CH contactor cycles error; 463 -* Precharge error (optional); 464 -* Critical error 465 - 466 -or one of the signals: 467 - 468 468 * Service reset; 469 469 * Power down request; 470 470 * Inhibit charging, 471 471 472 - bothcontactorsareopen (no current flows).440 +contactor open (no current flows). 473 473 474 474 When the algorithm "**On charger connected**" is selected, the control is performed as follows: 475 475