Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -165,10 +165,7 @@ 165 165 166 166 * the battery SOC is greater than the “Tolerant SOC” during the “Delay before clearing the signal” time. 167 167 168 -(% class="box infomessage" %) 169 -((( 170 170 The "Low SOC signal" is indicative and can be output to a discrete output or a power switch. 171 -))) 172 172 173 173 === High charging current (signal) === 174 174 ... ... @@ -193,10 +193,7 @@ 193 193 194 194 * the measured current is less than the “Tolerant charging current” value during the “Delay before clearing the signal” time. 195 195 196 -(% class="box infomessage" %) 197 -((( 198 198 The "High charging current" signal is indicative and can be output to a discrete output or a power switch. 199 -))) 200 200 201 201 === Charge map === 202 202 ... ... @@ -224,7 +224,7 @@ 224 224 225 225 Value of the charge current limit at given SOC, temperature, contactors temperature, maximum cell voltage and maximum cell temperature is calculated as follows: 226 226 227 - **Charging current limit = Maximum charging current × Kcs × Kcc × Kcv × Kct**221 +Charging current limit = Maximum charging current × Kcs × Kcc × Kcv × Kct 228 228 229 229 === Discharge map === 230 230 ... ... @@ -252,7 +252,7 @@ 252 252 253 253 Value of the discharge current limit at given SOC, temperature, contactors temperature, minimum cell voltage and maximum cell temperature is calculated as follows: 254 254 255 - **Discharging current limit = Maximum discharging current × Kds × Kdc × Kdv × Kdt**249 +Discharging current limit = Maximum discharging current × Kds × Kdc × Kdv × Kdt 256 256 257 257 === Charge map (PEAK & CONTINUOUS) === 258 258 ... ... @@ -348,11 +348,6 @@ 348 348 349 349 In “On demand” mode, the main contactor closes by external the “Close Main contactor” request. 350 350 351 -(% class="box infomessage" %) 352 -((( 353 -**Note: **when errors occur in the system, the **Main **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 354 -))) 355 - 356 356 To change the parameters of the main contactor, select the "Control → Main contactor" section: 357 357 358 358 [[image:1735064488658-863.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]] ... ... @@ -401,7 +401,7 @@ 401 401 * Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 402 402 * Errors 1, 2 to clear the "Ready to discharge" – bitfields to choose the errors which will clear the "Ready to discharge" signal. 403 403 404 -=== Precharge ()===393 +=== Precharge === 405 405 406 406 The BMS Main 3 device can control the precharge contactor. The precharge contactor is used to charge the intermediate capacity with low current and usually placed with the limiting resistor in parallel to charging or discharging contactor. 407 407 ... ... @@ -430,9 +430,9 @@ 430 430 * voltages before and after contactors are not equal after "Number of precharging attempts"; 431 431 * power dissipated on the precharge resistor is above the maximum value during the “Delay before setting the 'Precharge error' when checking power” time. 432 432 433 -(% class="box warningmessage" %)422 +(% class="box infomessage" %) 434 434 ((( 435 - Behavior ofcontactorsat “Precharge error”isconfiguredin corresponding contactorttings!424 +If there is the “Precharge error”, **charging **and **discharging **contactors open. 436 436 ))) 437 437 438 438 === Charge === ... ... @@ -485,7 +485,7 @@ 485 485 486 486 (% class="box infomessage" %) 487 487 ((( 488 - **Note:**when errors occur in the system, the **Charge**contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).477 +Note: when errors occur in the system, the **charging **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 489 489 ))) 490 490 491 491 To change the parameters of the battery charge control algorithm, select the "Control → Charge" section: ... ... @@ -556,7 +556,7 @@ 556 556 557 557 (% class="box infomessage" %) 558 558 ((( 559 -**Note: when errorsoccurin the system,theDischarge**contactor opens either immediately or withthedelay T,,off,, (depends on the settings described below).548 +**Note:** in case of errors in the system operation, **discharging **contactor opens either immediately or with a delay T,,off,, (depends on the settings described below). 560 560 ))) 561 561 562 562 The device supports controlling the precharging contactor. The duration of switching on the precharging contactor before closing the discharging (load) contactor is adjusted. ... ... @@ -591,11 +591,6 @@ 591 591 * Independent (Always) - Charge/Discharge contactor is always closed if there is no errors; 592 592 * Independent (on Charge request or Discharge request) - Charge/Discharge contactor is based on its own controller that listen to Charge and Discharge requests and closes if one of these signals occurs. 593 593 594 -(% class="box infomessage" %) 595 -((( 596 -**Note: **when errors occur in the system, the **Charge/Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 597 -))) 598 - 599 599 The charging/discharging contactor control is configured in the “Control – Charge/Discharge” section: 600 600 601 601 [[image:1735122153011-166.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="162" width="800"]] ... ... @@ -628,11 +628,6 @@ 628 628 * the battery voltage is out of range; 629 629 * the battery system errors are detected. 630 630 631 -(% class="box infomessage" %) 632 -((( 633 -**Note: **when errors occur in the system, the **Discharge (AUX) **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 634 -))) 635 - 636 636 To change the parameters of the powering of external equipment, select the "Control → Discharge (AUX)" section: 637 637 638 638 [[image:1735066190419-838.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="161" width="800"]] ... ... @@ -695,7 +695,7 @@ 695 695 * Minimum cell voltage to start balancing, V; 696 696 * Voltage deviation to start balancing; 697 697 * Voltage deviation to stop balancing; 698 -* Voltage for forced balancing – if cell voltage is above this value, it will start discharg ingthrough balancing resistor;677 +* Voltage for forced balancing – if cell voltage is above this value, it will start discharge through balancing resistor; 699 699 * Maximum allowable temperature of BMS Logic devices, ºC; 700 700 * Command to discharge all cells – a flag to force the balancing of all cells. 701 701 ... ... @@ -821,7 +821,7 @@ 821 821 822 822 (% class="box warningmessage" %) 823 823 ((( 824 -If there is the “High voltage fault”, **the “Critical error” is generated.** 803 +If there is the “High voltage fault”, **the “Critical error” is generated and all contactors open.** 825 825 ))) 826 826 827 827 === Cell analysis ===