Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -342,11 +342,6 @@ 342 342 343 343 In “On demand” mode, the main contactor closes by external the “Close Main contactor” request. 344 344 345 -(% class="box infomessage" %) 346 -((( 347 -**Note: **when errors occur in the system, the **Main **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 348 -))) 349 - 350 350 To change the parameters of the main contactor, select the "Control → Main contactor" section: 351 351 352 352 [[image:1735064488658-863.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]] ... ... @@ -424,9 +424,9 @@ 424 424 * voltages before and after contactors are not equal after "Number of precharging attempts"; 425 425 * power dissipated on the precharge resistor is above the maximum value during the “Delay before setting the 'Precharge error' when checking power” time. 426 426 427 -(% class="box warningmessage" %)422 +(% class="box infomessage" %) 428 428 ((( 429 - Behavior ofcontactorsat “Precharge error”isconfiguredin corresponding contactorttings!424 +If there is the “Precharge error”, **charging **and **discharging **contactors open. 430 430 ))) 431 431 432 432 === Charge === ... ... @@ -479,7 +479,7 @@ 479 479 480 480 (% class="box infomessage" %) 481 481 ((( 482 - **Note:**when errors occur in the system, the **Charge**contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).477 +Note: when errors occur in the system, the **charging **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 483 483 ))) 484 484 485 485 To change the parameters of the battery charge control algorithm, select the "Control → Charge" section: ... ... @@ -550,7 +550,7 @@ 550 550 551 551 (% class="box infomessage" %) 552 552 ((( 553 -**Note: when errorsoccurin the system,theDischarge**contactor opens either immediately or withthedelay T,,off,, (depends on the settings described below).548 +**Note:** in case of errors in the system operation, **discharging **contactor opens either immediately or with a delay T,,off,, (depends on the settings described below). 554 554 ))) 555 555 556 556 The device supports controlling the precharging contactor. The duration of switching on the precharging contactor before closing the discharging (load) contactor is adjusted. ... ... @@ -583,12 +583,8 @@ 583 583 584 584 * Dependent (on Charging and Discharging signals) - Charge/Discharge contactor depends on Charge and Discharge algorithms and their signals and behaves as Charging contactor if Charging signal is set, otherwise – as Discharging contactor; 585 585 * Independent (Always) - Charge/Discharge contactor is always closed if there is no errors; 586 -* Independent (on Charge request or Discharge request) - Charge/Discharge contactor is based on its own controller that listen to Charge and Discharge requests and closes if one of these signals occurs.581 +* Independent (on Charge request or Discharge request) - Charge/Discharge contactor is based on its own controller that listen to Charge and Discharge requests. 587 587 588 -(% class="box infomessage" %) 589 -((( 590 -**Note: **when errors occur in the system, the **Charge/Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 591 -))) 592 592 593 593 The charging/discharging contactor control is configured in the “Control – Charge/Discharge” section: 594 594 ... ... @@ -622,11 +622,6 @@ 622 622 * the battery voltage is out of range; 623 623 * the battery system errors are detected. 624 624 625 -(% class="box infomessage" %) 626 -((( 627 -**Note: **when errors occur in the system, the **Discharge (AUX) **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 628 -))) 629 - 630 630 To change the parameters of the powering of external equipment, select the "Control → Discharge (AUX)" section: 631 631 632 632 [[image:1735066190419-838.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="161" width="800"]] ... ... @@ -689,7 +689,7 @@ 689 689 * Minimum cell voltage to start balancing, V; 690 690 * Voltage deviation to start balancing; 691 691 * Voltage deviation to stop balancing; 692 -* Voltage for forced balancing – if cell voltage is above this value, it will startdischargingthrough balancing resistor;678 +* Voltage for forced balancing – if cell voltage is above this value, it will discharge through balancing resistor; 693 693 * Maximum allowable temperature of BMS Logic devices, ºC; 694 694 * Command to discharge all cells – a flag to force the balancing of all cells. 695 695 ... ... @@ -815,7 +815,7 @@ 815 815 816 816 (% class="box warningmessage" %) 817 817 ((( 818 -If there is the “High voltage fault”, **the “Critical error” is generated.** 804 +If there is the “High voltage fault”, **the “Critical error” is generated and all contactors open.** 819 819 ))) 820 820 821 821 === Cell analysis ===