... ... @@ -342,11 +342,6 @@
342 342  
343 343  In “On demand” mode, the main contactor closes by external the “Close Main contactor” request.
344 344  
345 -(% class="box infomessage" %)
346 -(((
347 -**Note: **when errors occur in the system, the **Main **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
348 -)))
349 -
350 350  To change the parameters of the main contactor, select the "Control → Main contactor" section:
351 351  
352 352  [[image:1735064488658-863.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]]
... ... @@ -479,7 +479,7 @@
479 479  
480 480  (% class="box infomessage" %)
481 481  (((
482 -**Note: **when errors occur in the system, the **Charge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
477 +**Note: **when errors occur in the system, the **charging **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
483 483  )))
484 484  
485 485  To change the parameters of the battery charge control algorithm, select the "Control → Charge" section:
... ... @@ -550,7 +550,7 @@
550 550  
551 551  (% class="box infomessage" %)
552 552  (((
553 -**Note: **when errors occur in the system, the **Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
548 +**Note:** in case of errors in the system operation, **discharging **contactor opens either immediately or with a delay T,,off,, (depends on the settings described below).
554 554  )))
555 555  
556 556  The device supports controlling the precharging contactor. The duration of switching on the precharging contactor before closing the discharging (load) contactor is adjusted.
... ... @@ -587,7 +587,7 @@
587 587  
588 588  (% class="box infomessage" %)
589 589  (((
590 -**Note: **when errors occur in the system, the **Charge/Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
585 +**Note: **when errors occur in the system, the **charge/Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
591 591  )))
592 592  
593 593  The charging/discharging contactor control is configured in the “Control – Charge/Discharge” section:
... ... @@ -815,7 +815,7 @@
815 815  
816 816  (% class="box warningmessage" %)
817 817  (((
818 -If there is the “High voltage fault”, **the “Critical error” is generated.**
813 +If there is the “High voltage fault”, **the “Critical error” is generated and all contactors open.**
819 819  )))
820 820  
821 821  === Cell analysis ===