Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -342,6 +342,11 @@ 342 342 343 343 In “On demand” mode, the main contactor closes by external the “Close Main contactor” request. 344 344 345 +(% class="box infomessage" %) 346 +((( 347 +**Note: **when errors occur in the system, the **Main **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 348 +))) 349 + 345 345 To change the parameters of the main contactor, select the "Control → Main contactor" section: 346 346 347 347 [[image:1735064488658-863.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="112" width="800"]] ... ... @@ -474,7 +474,7 @@ 474 474 475 475 (% class="box infomessage" %) 476 476 ((( 477 -**Note: **when errors occur in the system, the ** charging**contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).482 +**Note: **when errors occur in the system, the **Charge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 478 478 ))) 479 479 480 480 To change the parameters of the battery charge control algorithm, select the "Control → Charge" section: ... ... @@ -545,7 +545,7 @@ 545 545 546 546 (% class="box infomessage" %) 547 547 ((( 548 -**Note:** incaseof errors in the systemoperation,**discharging**contactor opens either immediately or withadelay T,,off,, (depends on the settings described below).553 +**Note: **when errors occur in the system, the **Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 549 549 ))) 550 550 551 551 The device supports controlling the precharging contactor. The duration of switching on the precharging contactor before closing the discharging (load) contactor is adjusted. ... ... @@ -582,7 +582,7 @@ 582 582 583 583 (% class="box infomessage" %) 584 584 ((( 585 -**Note: **when errors occur in the system, the ** charge/Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).590 +**Note: **when errors occur in the system, the **Charge/Discharge **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 586 586 ))) 587 587 588 588 The charging/discharging contactor control is configured in the “Control – Charge/Discharge” section: ... ... @@ -810,7 +810,7 @@ 810 810 811 811 (% class="box warningmessage" %) 812 812 ((( 813 -If there is the “High voltage fault”, **the “Critical error” is generated and all contactors open.**818 +If there is the “High voltage fault”, **the “Critical error” is generated.** 814 814 ))) 815 815 816 816 === Cell analysis ===