... ... @@ -394,7 +394,7 @@
394 394  
395 395  The BMS Main 3 device can control the precharge contactor. The precharge contactor is used to charge the intermediate capacity with low current and usually placed with the limiting resistor in parallel to charging or discharging contactor.
396 396  
397 -BMS Main 3 device detects errors while pre-charging the load capacity by monitoring the current and voltage difference before and after contactors. Also BMS can measure the power dissipated on precharge resistor and generate an error if it greater than configured limit.
397 +BMS Main 3 device detects errors while pre-charging the load capacity by monitoring the current and voltage difference before and after contactors.
398 398  
399 399  To change the parameters of precharge contactor, select the "Control → Precharge" section:
400 400  
... ... @@ -580,7 +580,6 @@
580 580  * Independent (Always) - Charge/Discharge contactor is always closed if there is no errors;
581 581  * Independent (on Charge request or Discharge request) - Charge/Discharge contactor is based on its own controller that listen to Charge and Discharge requests.
582 582  
583 -
584 584  The charging/discharging contactor control is configured in the “Control – Charge/Discharge” section:
585 585  
586 586  [[image:1735122153011-166.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="162" width="800"]]