413 413  * Delay before clearing the "Precharge error", second;
414 414  * Lock the "Precharge error" – a flag to block the error until the device is restarted.
415 415  
416 +
416 416  “Precharge error” generation conditions:
417 417  
418 418  * the precharge current does not decrease after "Number of precharging attempts";
... ... @@ -572,33 +572,15 @@
572 572  
573 573  === Charge/Discharge ===
574 574  
575 -The BMS Main 3 device can control the charge/discharge contactor, which combines algorithms of charging and discharging contactor.
576 +The BMS Main 3 device can control the charging/discharging contactor, which combines algorithms of charging and discharging contactor. It behaves as a charging contactor when “Charge request” or “Charger connected” is set, otherwise – as a discharging contactor.
576 576  
577 -Charge/Discharge contactor has three algorithms of operation:
578 -
579 -* Dependent (on Charging and Discharging signals) - Charge/Discharge contactor depends on Charge and Discharge algorithms and their signals and behaves as Charging contactor if Charging signal is set, otherwise – as Discharging contactor;
580 -* Independent (Always) - Charge/Discharge contactor is always closed if there is no errors;
581 -* Independent (on Charge request or Discharge request) - Charge/Discharge contactor is based on its own controller that listen to Charge and Discharge requests.
582 -
583 583  The charging/discharging contactor control is configured in the “Control – Charge/Discharge” section:
584 584  
585 -[[image:1735122153011-166.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="162" width="800"]]
580 +[[image:1733322827919-875.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="85" width="800"]]
586 586  
587 587  In this section:
588 588  
589 589  * Enable – a flag to enable the charge/discharge controller.
590 -* Algorithm:
591 -** Dependent (on Charging and Discharging signals) - Charge/Discharge contactor depends on Charge and Discharge algorithms and their signals and behaves as Charging contactor if Charging signal is set, otherwise – as Discharging contactor;
592 -** Independent (Always) - Charge/Discharge contactor is always closed if there is no errors;
593 -** Independent (on Charge request or Discharge request);
594 -* Delay before starting charging or discharging, millisecond;
595 -* Delay before stopping charging or discharging, millisecond;
596 -* Control the precharging contactor – a flag that enables control of precharging contactor while closing the charge/discharge contactor;
597 -* Emulate the "Charging" and "Discharging" signals – a flag to enable generation of "Charging" and "Discharging" signals when closing charge/discharge contactor;
598 -* Errors 1, 2 to prevent CHARGING through charging/discharging contactor, Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor – bitfields to choose the errors which will open the charging/discharging contactor. This bitfields are combined by bitwise OR and intended to separate settings for charging and discharging processes;
599 -* Errors 1, 2 which affect the contactor only if battery CHARGING is detected – a bitfield to choose the errors which will trigger only if charging current is present. This bitfield is combined with "Errors 1, 2 to prevent CHARGING through charging/discharging contactor" by bitwise AND;
600 -* Errors 1, 2 which affect the contactor only if battery DISCHARGING is detected – a bitfield to choose the errors which will trigger only if discharging current is present. This bitfield is combined with "Errors 1, 2 to prevent DISCHARGING through charging/discharging contactor" by bitwise AND;
601 -* Switch off the charging/discharging contactor on errors without delay – a flag to protectively open the charging/discharging contactor without a delay. In the opposite case, when an error is detected, the charging/discharging contactor opens always with the delay “Delay before stopping discharging”.
602 602  