... ... @@ -413,7 +413,6 @@
413 413  * Delay before clearing the "Precharge error", second;
414 414  * Lock the "Precharge error" – a flag to block the error until the device is restarted.
415 415  
416 -
417 417  “Precharge error” generation conditions:
418 418  
419 419  * the precharge current does not decrease after "Number of precharging attempts";
... ... @@ -573,11 +573,15 @@
573 573  
574 574  === Charge/Discharge ===
575 575  
576 -The BMS Main 3 device can control the charging/discharging contactor, which combines algorithms of charging and discharging contactor. It behaves as a charging contactor when “Charge request” or “Charger connected” is set, otherwise – as a discharging contactor.
575 +The BMS Main 3 device can control the charge/discharge contactor, which combines algorithms of charging and discharging contactor.
577 577  
577 +Charge/Discharge contactor has three algorithms of operation:
578 +
579 +Dependent (on Charging and Discharging signals) - Charging/Discharging contactor depends on Charging and Discharging algorithms and their signals. If
580 +
578 578  The charging/discharging contactor control is configured in the “Control – Charge/Discharge” section:
579 579  
580 -[[image:1733322827919-875.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="85" width="800"]]
583 +[[image:1735122153011-166.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="162" width="800"]]
581 581  
582 582  In this section:
583 583  
1735122153011-166.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +54.3 KB
Content