Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -359,8 +359,6 @@ 359 359 360 360 === Charging status === 361 361 362 -* Current corresponding to charging – a current level to generate the "Charging current present" signal, A; 363 -* Current corresponding to no charging – a current level to clear the "Charging current present" signal, A; 364 364 * Voltage to clear the “Ready to charge” – a threshold voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 365 365 * Voltage to reset the “Ready to charge” – a tolerant voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 366 366 * Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0. ... ... @@ -374,8 +374,6 @@ 374 374 375 375 === Discharging status === 376 376 377 -* Current corresponding to discharging – a current level to generate the "Discharging current present" signal, А; 378 -* Current indicating no discharging – a current level to clear the "Discharging current present" signal, А; 379 379 * Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 380 380 * Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 381 381 ... ... @@ -448,6 +448,8 @@ 448 448 ** On charger connected – charging is allowed when there is a signal “Charger connected”; 449 449 ** On charge request – charging is allowed when there is a signal “Charge request”; 450 450 * Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared; 447 +* Current corresponding to charging – a current level to generate the "Charging current present" signal, A; 448 +* Current corresponding to no charging – a current level to clear the "Charging current present" signal, A; 451 451 * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; 452 452 * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond; 453 453 * Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor; ... ... @@ -511,7 +511,7 @@ 511 511 512 512 To change the parameters of the battery discharge control algorithm, select the "Control → Discharge" section: 513 513 514 -[[image:173506 4038329-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="273" width="800"]]512 +[[image:1733323750262-841.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="360" width="800"]] 515 515 516 516 In this section: 517 517 ... ... @@ -520,11 +520,12 @@ 520 520 ** Always on – load is always connected; 521 521 ** On charger disconnected – load is connected when there is no signal “Charger connected”; 522 522 ** On discharge request – load is connected when there is signal “Discharge request”; 523 -* Allow charging only when the "Ready to discharge" signal is set – discharging contactor will open if "Ready to discharge" signal is cleared; 521 +* Current corresponding to discharging – a current level to generate the "Discharging current present" signal, А; 522 +* Current indicating no discharging – a current level to clear the "Discharging current present" signal, А; 524 524 * Delay before starting discharging – a time delay T,,on,, before closing the discharging contactor, millisecond; 525 525 * Delay before stopping discharging – a time delay T,,off,, before opening the discharging contactor, millisecond; 526 526 * Control the precharging contactor – a flag that allows control of the precharging contactor while closing the discharge contactor; 527 -* Errors 1, 2 to open the discharging contactor – bitfields to choose the errors which will open the discharging contactor;526 +* Errors 1, 2 to open the discharging contactor – bitfields to choose the errors which will open the charging contactor; 528 528 * Use custom delays before stopping discharging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 529 529 * Custom delay: <error> – specific error delay, millisecond; 530 530 * Switch off the discharging contactor on errors without delay – a flag to protectively open the discharging contactor without a delay. In the opposite case, when an error is detected, the discharging contactor opens always with the delay “Delay before stopping discharging”.
- 1735064362593-844.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -35.8 KB - Content