Changes for page 3.3 Control

Last modified by Admin on 2025/04/09 12:14

From version 13.2
edited by Admin
on 2024/12/24 18:14
Change comment: There is no comment for this version
To version 17.1
edited by Admin
on 2024/12/24 18:20
Change comment: Uploaded new attachment "1735064454708-345.png", version {1}

Summary

Details

Page properties
Content
... ... @@ -359,6 +359,8 @@
359 359  
360 360  === Charging status ===
361 361  
362 +* Current corresponding to charging – a current level to generate the "Charging current present" signal, A;
363 +* Current corresponding to no charging – a current level to clear the "Charging current present" signal, A;
362 362  * Voltage to clear the “Ready to charge” – a threshold voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared;
363 363  * Voltage to reset the “Ready to charge” – a tolerant voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set;
364 364  * Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0.
... ... @@ -372,6 +372,8 @@
372 372  
373 373  === Discharging status ===
374 374  
377 +* Current corresponding to discharging – a current level to generate the "Discharging current present" signal, А;
378 +* Current indicating no discharging – a current level to clear the "Discharging current present" signal, А;
375 375  * Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared;
376 376  * Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set;
377 377  
... ... @@ -444,8 +444,6 @@
444 444  ** On charger connected – charging is allowed when there is a signal “Charger connected”;
445 445  ** On charge request – charging is allowed when there is a signal “Charge request”;
446 446  * Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared;
447 -* Current corresponding to charging – a current level to generate the "Charging current present" signal, A;
448 -* Current corresponding to no charging – a current level to clear the "Charging current present" signal, A;
449 449  * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond;
450 450  * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond;
451 451  * Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor;
... ... @@ -518,9 +518,7 @@
518 518  ** Always on – load is always connected;
519 519  ** On charger disconnected – load is connected when there is no signal “Charger connected”;
520 520  ** On discharge request – load is connected when there is signal “Discharge request”;
521 -* Allow charging only when the "Ready to discharge" signal is set – charging contactor will open if "Ready to charge" signal is cleared;
522 -* Current corresponding to discharging – a current level to generate the "Discharging current present" signal, А;
523 -* Current indicating no discharging – a current level to clear the "Discharging current present" signal, А;
523 +* Allow charging only when the "Ready to discharge" signal is set – discharging contactor will open if "Ready to discharge" signal is cleared;
524 524  * Delay before starting discharging – a time delay T,,on,, before closing the discharging contactor, millisecond;
525 525  * Delay before stopping discharging – a time delay T,,off,, before opening the discharging contactor, millisecond;
526 526  * Control the precharging contactor – a flag that allows control of the precharging contactor while closing the discharge contactor;
1735064362593-844.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +35.8 KB
Content
1735064399985-526.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +36.1 KB
Content
1735064434321-430.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +27.5 KB
Content
1735064454708-345.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +27.7 KB
Content