Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -448,7 +448,7 @@ 448 448 * Current corresponding to no charging – a current level to clear the "Charging current present" signal, A; 449 449 * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; 450 450 * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond; 451 -* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor;451 +* Control the precharging contactor – a flag that allows control of the precharging contactor; 452 452 * Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor; 453 453 * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 454 454 * Custom delay: <error> – delay for specific error, millisecond; ... ... @@ -509,7 +509,7 @@ 509 509 510 510 To change the parameters of the battery discharge control algorithm, select the "Control → Discharge" section: 511 511 512 -[[image:173506 4038329-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="273" width="800"]]512 +[[image:1733323750262-841.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="360" width="800"]] 513 513 514 514 In this section: 515 515 ... ... @@ -518,16 +518,16 @@ 518 518 ** Always on – load is always connected; 519 519 ** On charger disconnected – load is connected when there is no signal “Charger connected”; 520 520 ** On discharge request – load is connected when there is signal “Discharge request”; 521 -* Allow charging only when the "Ready to discharge" signal is set – charging contactor will open if "Ready to charge" signal is cleared; 522 522 * Current corresponding to discharging – a current level to generate the "Discharging current present" signal, А; 523 523 * Current indicating no discharging – a current level to clear the "Discharging current present" signal, А; 524 524 * Delay before starting discharging – a time delay T,,on,, before closing the discharging contactor, millisecond; 525 525 * Delay before stopping discharging – a time delay T,,off,, before opening the discharging contactor, millisecond; 526 -* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the discharge contactor; 527 -* Errors 1, 2 to open the discharging contactor – bitfields to choose the errors which will open the discharging contactor; 528 528 * Use custom delays before stopping discharging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 529 529 * Custom delay: <error> – specific error delay, millisecond; 530 530 * Switch off the discharging contactor on errors without delay – a flag to protectively open the discharging contactor without a delay. In the opposite case, when an error is detected, the discharging contactor opens always with the delay “Delay before stopping discharging”. 528 +* Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 529 +* Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor; 530 +* Minimum voltage difference to finish precharging – minimal voltage difference before and after contactors at which precharge process is meant to be finished, V; 531 531 532 532 === Charge/Discharge === 533 533
- 1735064038329-836.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -62.0 KB - Content