Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 3 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -359,6 +359,8 @@ 359 359 360 360 === Charging status === 361 361 362 +* Current corresponding to charging – a current level to generate the "Charging current present" signal, A; 363 +* Current corresponding to no charging – a current level to clear the "Charging current present" signal, A; 362 362 * Voltage to clear the “Ready to charge” – a threshold voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 363 363 * Voltage to reset the “Ready to charge” – a tolerant voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 364 364 * Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0. ... ... @@ -372,6 +372,8 @@ 372 372 373 373 === Discharging status === 374 374 377 +* Current corresponding to discharging – a current level to generate the "Discharging current present" signal, А; 378 +* Current indicating no discharging – a current level to clear the "Discharging current present" signal, А; 375 375 * Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 376 376 * Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 377 377 ... ... @@ -444,8 +444,6 @@ 444 444 ** On charger connected – charging is allowed when there is a signal “Charger connected”; 445 445 ** On charge request – charging is allowed when there is a signal “Charge request”; 446 446 * Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared; 447 -* Current corresponding to charging – a current level to generate the "Charging current present" signal, A; 448 -* Current corresponding to no charging – a current level to clear the "Charging current present" signal, A; 449 449 * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; 450 450 * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond; 451 451 * Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor; ... ... @@ -509,7 +509,7 @@ 509 509 510 510 To change the parameters of the battery discharge control algorithm, select the "Control → Discharge" section: 511 511 512 -[[image:173 3323750262-841.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="360" width="800"]]514 +[[image:1735064038329-836.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="273" width="800"]] 513 513 514 514 In this section: 515 515 ... ... @@ -518,12 +518,11 @@ 518 518 ** Always on – load is always connected; 519 519 ** On charger disconnected – load is connected when there is no signal “Charger connected”; 520 520 ** On discharge request – load is connected when there is signal “Discharge request”; 521 -* Current corresponding to discharging – a current level to generate the "Discharging current present" signal, А; 522 -* Current indicating no discharging – a current level to clear the "Discharging current present" signal, А; 523 +* Allow charging only when the "Ready to discharge" signal is set – discharging contactor will open if "Ready to discharge" signal is cleared; 523 523 * Delay before starting discharging – a time delay T,,on,, before closing the discharging contactor, millisecond; 524 524 * Delay before stopping discharging – a time delay T,,off,, before opening the discharging contactor, millisecond; 525 525 * Control the precharging contactor – a flag that allows control of the precharging contactor while closing the discharge contactor; 526 -* Errors 1, 2 to open the discharging contactor – bitfields to choose the errors which will open the charging contactor; 527 +* Errors 1, 2 to open the discharging contactor – bitfields to choose the errors which will open the discharging contactor; 527 527 * Use custom delays before stopping discharging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 528 528 * Custom delay: <error> – specific error delay, millisecond; 529 529 * Switch off the discharging contactor on errors without delay – a flag to protectively open the discharging contactor without a delay. In the opposite case, when an error is detected, the discharging contactor opens always with the delay “Delay before stopping discharging”.
- 1735064362593-844.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +35.8 KB - Content
- 1735064399985-526.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +36.1 KB - Content
- 1735064434321-430.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +27.5 KB - Content