... ... @@ -448,7 +448,7 @@
448 448  * Current corresponding to no charging – a current level to clear the "Charging current present" signal, A;
449 449  * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond;
450 450  * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond;
451 -* Control the precharging contactor – a flag that allows control of the precharging contactor;
451 +* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the charge contactor;
452 452  * Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor;
453 453  * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors;
454 454  * Custom delay: <error> – delay for specific error, millisecond;
... ... @@ -522,12 +522,11 @@
522 522  * Current indicating no discharging – a current level to clear the "Discharging current present" signal, А;
523 523  * Delay before starting discharging – a time delay T,,on,, before closing the discharging contactor, millisecond;
524 524  * Delay before stopping discharging – a time delay T,,off,, before opening the discharging contactor, millisecond;
525 +* Control the precharging contactor – a flag that allows control of the precharging contactor while closing the discharge contactor;
526 +* Errors 1, 2 to open the discharging contactor – bitfields to choose the errors which will open the charging contactor;
525 525  * Use custom delays before stopping discharging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors;
526 526  * Custom delay: <error> – specific error delay, millisecond;
527 527  * Switch off the discharging contactor on errors without delay – a flag to protectively open the discharging contactor without a delay. In the opposite case, when an error is detected, the discharging contactor opens always with the delay “Delay before stopping discharging”.
528 -* Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond;
529 -* Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor;
530 -* Minimum voltage difference to finish precharging – minimal voltage difference before and after contactors at which precharge process is meant to be finished, V;
531 531  