... ... @@ -407,8 +407,8 @@
407 407  
408 408  or one of the signals:
409 409  
410 -* Service reset;
411 -* Power down request;
410 +* Service reset
411 +* Power down request
412 412  * Inhibit charging,
413 413  
414 414  both contactors are open (no current flows).
... ... @@ -500,10 +500,7 @@
500 500  * if there is signal “Discharge request”, the charging contactor is open and there are no errors (see the list above), then through the delay time T,,on,, the discharging contactor closes;
501 501  * If the signal “Discharge request” disappears or errors occur (see the list above), then after the delay time T,,off,, the discharging contactor opens.
502 502  
503 -(% class="box infomessage" %)
504 -(((
505 -**Note:** in case of errors in the system operation, **discharging **contactor opens either immediately or with a delay T,,off,, (depends on the settings described below).
506 -)))
503 +Note – In case of errors in the system operation, the opening of the discharging contactor is performed either immediately or with a delay T,,off,, (depends on the settings described below).