Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -359,21 +359,11 @@ 359 359 360 360 === Charging status === 361 361 362 -* Voltage to clear the “Ready to charge” – a threshold voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 363 -* Voltage to reset the “Ready to charge” – a tolerant voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 364 -* Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0. 362 +TBA 365 365 366 -(% class="box infomessage" %) 367 -((( 368 -**Note:** The "Allow charging" signal activates under two independent conditions: 369 -1) the voltage on the cells reaches the “Voltage to reset the “Ready to charge"” level and 370 -2) the "Delay before recharging" time has passed since the opening of the allow charging contactor. 371 -))) 372 - 373 373 === Discharging status === 374 374 375 -* Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 376 -* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 366 +TBA 377 377 378 378 === Precharge === 379 379 ... ... @@ -407,9 +407,9 @@ 407 407 408 408 or one of the signals: 409 409 410 -* Service reset ;411 -* Power down request ;412 -* Inhibit charging ,400 +* Service reset 401 +* Power down request 402 +* Inhibit charging 413 413 414 414 both contactors are open (no current flows). 415 415 ... ... @@ -427,14 +427,11 @@ 427 427 * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed); 428 428 * If errors in the list above occur the charging contactor and allow charging contactor open. 429 429 430 -(% class="box infomessage" %) 431 -((( 432 -Note: when errors occur in the system, the **charging **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 433 -))) 420 +Note – When errors occur in the system, the charging contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 434 434 435 435 To change the parameters of the battery charge control algorithm, select the "Control → Charge" section: 436 436 437 -[[image:173 5063563460-549.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]]424 +[[image:1733322798914-813.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="327" width="800"]] 438 438 439 439 In this section: 440 440 ... ... @@ -443,17 +443,20 @@ 443 443 ** Always on – charging is always allowed; 444 444 ** On charger connected – charging is allowed when there is a signal “Charger connected”; 445 445 ** On charge request – charging is allowed when there is a signal “Charge request”; 446 -* Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared; 447 447 * Current corresponding to charging – a current level to generate the "Charging current present" signal, A; 448 448 * Current corresponding to no charging – a current level to clear the "Charging current present" signal, A; 449 449 * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; 450 450 * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond; 451 -* Control the precharging contactor – a flag that allows control of the precharging contactor; 452 -* Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor; 453 453 * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 454 -* Custom delay: <error> – delay forspecific error, millisecond;438 +* Custom delay: <error> – specific error delay, millisecond; 455 455 * Switch off the charging contactor on errors without delay – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging”; 440 +* Control the precharging contactor – a flag that allows control of the precharging contactor; 441 +* Voltage to clear the “Ready to charge” – a threshold voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 442 +* Voltage to reset the “Ready to charge” – a tolerant voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 443 +* Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0. 456 456 445 +Note – The allow charging contactor closes under two independent conditions: 1) the voltage on the cells reaches the “Voltage to reset the “Ready to charge"” level and 2) the "Delay before recharging" time has passed since the opening of the allow charging contactor. 446 + 457 457 === Discharge === 458 458 459 459 The device controls the discharging contactor to connect battery to the load. ... ... @@ -500,10 +500,7 @@ 500 500 * if there is signal “Discharge request”, the charging contactor is open and there are no errors (see the list above), then through the delay time T,,on,, the discharging contactor closes; 501 501 * If the signal “Discharge request” disappears or errors occur (see the list above), then after the delay time T,,off,, the discharging contactor opens. 502 502 503 -(% class="box infomessage" %) 504 -((( 505 -**Note:** in case of errors in the system operation, **discharging **contactor opens either immediately or with a delay T,,off,, (depends on the settings described below). 506 -))) 493 +Note – In case of errors in the system operation, the opening of the discharging contactor is performed either immediately or with a delay T,,off,, (depends on the settings described below). 507 507 508 508 The device supports controlling the precharging contactor. The duration of switching on the precharging contactor before closing the discharging (load) contactor is adjusted. 509 509 ... ... @@ -528,6 +528,8 @@ 528 528 * Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 529 529 * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor; 530 530 * Minimum voltage difference to finish precharging – minimal voltage difference before and after contactors at which precharge process is meant to be finished, V; 518 +* Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 519 +* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 531 531 532 532 === Charge/Discharge === 533 533
- 1735063563460-549.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -59.6 KB - Content