... ... @@ -409,7 +409,7 @@
409 409  
410 410  * Service reset
411 411  * Power down request
412 -* Inhibit charging,
412 +* Inhibit charging
413 413  
414 414  both contactors are open (no current flows).
415 415  
... ... @@ -427,10 +427,7 @@
427 427  * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed);
428 428  * If errors in the list above occur the charging contactor and allow charging contactor open.
429 429  
430 -(% class="box infomessage" %)
431 -(((
432 -Note: when errors occur in the system, the **charging **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
433 -)))
430 +Note – When errors occur in the system, the charging contactor opens either immediately or with the delay T,,off,, (depends on the settings described below).
434 434  
435 435  To change the parameters of the battery charge control algorithm, select the "Control → Charge" section:
436 436  
... ... @@ -449,9 +449,9 @@
449 449  * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond;
450 450  * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond;
451 451  * Control the precharging contactor – a flag that allows control of the precharging contactor;
452 -* Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor;
449 +* Errors 1, 2 
453 453  * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors;
454 -* Custom delay: <error> – delay for specific error, millisecond;
451 +* Custom delay: <error> – specific error delay, millisecond;
455 455  * Switch off the charging contactor on errors without delay – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging”;
456 456  
457 457  === Discharge ===