Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -409,7 +409,7 @@ 409 409 410 410 * Service reset 411 411 * Power down request 412 -* Inhibit charging ,412 +* Inhibit charging 413 413 414 414 both contactors are open (no current flows). 415 415 ... ... @@ -427,10 +427,7 @@ 427 427 * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed); 428 428 * If errors in the list above occur the charging contactor and allow charging contactor open. 429 429 430 -(% class="box infomessage" %) 431 -((( 432 -Note: when errors occur in the system, the **charging **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 433 -))) 430 +Note – When errors occur in the system, the charging contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 434 434 435 435 To change the parameters of the battery charge control algorithm, select the "Control → Charge" section: 436 436 ... ... @@ -443,15 +443,14 @@ 443 443 ** Always on – charging is always allowed; 444 444 ** On charger connected – charging is allowed when there is a signal “Charger connected”; 445 445 ** On charge request – charging is allowed when there is a signal “Charge request”; 446 -* Allow charging only when the "Ready to charge" signal is set– charging contactor will open if "Ready to charge" signal is cleared;443 +* Allow charging only when the "Ready to charge" signal is et 447 447 * Current corresponding to charging – a current level to generate the "Charging current present" signal, A; 448 448 * Current corresponding to no charging – a current level to clear the "Charging current present" signal, A; 449 449 * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; 450 450 * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond; 451 451 * Control the precharging contactor – a flag that allows control of the precharging contactor; 452 -* Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor; 453 453 * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 454 -* Custom delay: <error> – delay forspecific error, millisecond;450 +* Custom delay: <error> – specific error delay, millisecond; 455 455 * Switch off the charging contactor on errors without delay – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging”; 456 456 457 457 === Discharge ===