Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -407,9 +407,9 @@ 407 407 408 408 or one of the signals: 409 409 410 -* Service reset 411 -* Power down request 412 -* Inhibit charging 410 +* Service reset; 411 +* Power down request; 412 +* Inhibit charging, 413 413 414 414 both contactors are open (no current flows). 415 415 ... ... @@ -427,7 +427,10 @@ 427 427 * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed); 428 428 * If errors in the list above occur the charging contactor and allow charging contactor open. 429 429 430 -Note – When errors occur in the system, the charging contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 430 +(% class="box infomessage" %) 431 +((( 432 +Note: when errors occur in the system, the **charging **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 433 +))) 431 431 432 432 To change the parameters of the battery charge control algorithm, select the "Control → Charge" section: 433 433 ... ... @@ -446,9 +446,9 @@ 446 446 * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; 447 447 * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond; 448 448 * Control the precharging contactor – a flag that allows control of the precharging contactor; 449 -* Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor 452 +* Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor; 450 450 * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 451 -* Custom delay: <error> – specific error delay, millisecond;454 +* Custom delay: <error> – delay for specific error, millisecond; 452 452 * Switch off the charging contactor on errors without delay – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging”; 453 453 454 454 === Discharge === ... ... @@ -497,7 +497,10 @@ 497 497 * if there is signal “Discharge request”, the charging contactor is open and there are no errors (see the list above), then through the delay time T,,on,, the discharging contactor closes; 498 498 * If the signal “Discharge request” disappears or errors occur (see the list above), then after the delay time T,,off,, the discharging contactor opens. 499 499 500 -Note – In case of errors in the system operation, the opening of the discharging contactor is performed either immediately or with a delay T,,off,, (depends on the settings described below). 503 +(% class="box infomessage" %) 504 +((( 505 +**Note:** in case of errors in the system operation, **discharging **contactor opens either immediately or with a delay T,,off,, (depends on the settings described below). 506 +))) 501 501 502 502 The device supports controlling the precharging contactor. The duration of switching on the precharging contactor before closing the discharging (load) contactor is adjusted. 503 503