... ... @@ -372,8 +372,7 @@
372 372  
373 373  === Discharging status ===
374 374  
375 -* Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared;
376 -* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set;
375 +TBA
377 377  
378 378  === Precharge ===
379 379  
... ... @@ -431,7 +431,7 @@
431 431  
432 432  To change the parameters of the battery charge control algorithm, select the "Control → Charge" section:
433 433  
434 -[[image:1735063563460-549.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]]
433 +[[image:1735063563460-549.png]]
435 435  
436 436  In this section:
437 437  
... ... @@ -440,7 +440,6 @@
440 440  ** Always on – charging is always allowed;
441 441  ** On charger connected – charging is allowed when there is a signal “Charger connected”;
442 442  ** On charge request – charging is allowed when there is a signal “Charge request”;
443 -* Allow charging only when the "Ready to charge" signal is set
444 444  * Current corresponding to charging – a current level to generate the "Charging current present" signal, A;
445 445  * Current corresponding to no charging – a current level to clear the "Charging current present" signal, A;
446 446  * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond;
... ... @@ -521,6 +521,8 @@
521 521  * Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond;
522 522  * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor;
523 523  * Minimum voltage difference to finish precharging – minimal voltage difference before and after contactors at which precharge process is meant to be finished, V;
522 +* Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared;
523 +* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set;
524 524  
525 525  === Charge/Discharge ===
526 526