Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -409,7 +409,7 @@ 409 409 410 410 * Service reset 411 411 * Power down request 412 -* Inhibit charging 412 +* Inhibit charging, 413 413 414 414 both contactors are open (no current flows). 415 415 ... ... @@ -427,7 +427,10 @@ 427 427 * If in the process of charging the voltage on the cell exceeds the “Ready to charge” level, the allow charging contactor opens (while the charging contactor remains closed); 428 428 * If errors in the list above occur the charging contactor and allow charging contactor open. 429 429 430 -Note – When errors occur in the system, the charging contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 430 +(% class="box infomessage" %) 431 +((( 432 +Note: when errors occur in the system, the **charging **contactor opens either immediately or with the delay T,,off,, (depends on the settings described below). 433 +))) 431 431 432 432 To change the parameters of the battery charge control algorithm, select the "Control → Charge" section: 433 433 ... ... @@ -440,14 +440,15 @@ 440 440 ** Always on – charging is always allowed; 441 441 ** On charger connected – charging is allowed when there is a signal “Charger connected”; 442 442 ** On charge request – charging is allowed when there is a signal “Charge request”; 443 -* Allow charging only when the "Ready to charge" signal is et 446 +* Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared; 444 444 * Current corresponding to charging – a current level to generate the "Charging current present" signal, A; 445 445 * Current corresponding to no charging – a current level to clear the "Charging current present" signal, A; 446 446 * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; 447 447 * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond; 448 448 * Control the precharging contactor – a flag that allows control of the precharging contactor; 452 +* Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor; 449 449 * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 450 -* Custom delay: <error> – specific error delay, millisecond;454 +* Custom delay: <error> – delay for specific error, millisecond; 451 451 * Switch off the charging contactor on errors without delay – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging”; 452 452 453 453 === Discharge ===