... ... @@ -440,12 +440,13 @@
440 440  ** Always on – charging is always allowed;
441 441  ** On charger connected – charging is allowed when there is a signal “Charger connected”;
442 442  ** On charge request – charging is allowed when there is a signal “Charge request”;
443 -* Allow charging only when the "Ready to charge" signal is et
443 +* Allow charging only when the "Ready to charge" signal is set – charging contactor will open if "Ready to charge" signal is cleared;
444 444  * Current corresponding to charging – a current level to generate the "Charging current present" signal, A;
445 445  * Current corresponding to no charging – a current level to clear the "Charging current present" signal, A;
446 446  * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond;
447 447  * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond;
448 448  * Control the precharging contactor – a flag that allows control of the precharging contactor;
449 +* Errors 1, 2 to open the charging contactor – bitfields to choose the errors which will open the charging contactor
449 449  * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors;
450 450  * Custom delay: <error> – specific error delay, millisecond;
451 451  * Switch off the charging contactor on errors without delay – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging”;