Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -372,8 +372,7 @@ 372 372 373 373 === Discharging status === 374 374 375 -* Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 376 -* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 375 +TBA 377 377 378 378 === Precharge === 379 379 ... ... @@ -431,7 +431,7 @@ 431 431 432 432 To change the parameters of the battery charge control algorithm, select the "Control → Charge" section: 433 433 434 -[[image:1735063563460-549.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]]433 +[[image:1735063563460-549.png]] 435 435 436 436 In this section: 437 437 ... ... @@ -440,7 +440,6 @@ 440 440 ** Always on – charging is always allowed; 441 441 ** On charger connected – charging is allowed when there is a signal “Charger connected”; 442 442 ** On charge request – charging is allowed when there is a signal “Charge request”; 443 -* Allow charging only when the "Ready to charge" signal is et 444 444 * Current corresponding to charging – a current level to generate the "Charging current present" signal, A; 445 445 * Current corresponding to no charging – a current level to clear the "Charging current present" signal, A; 446 446 * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; ... ... @@ -521,6 +521,8 @@ 521 521 * Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 522 522 * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor; 523 523 * Minimum voltage difference to finish precharging – minimal voltage difference before and after contactors at which precharge process is meant to be finished, V; 522 +* Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 523 +* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 524 524 525 525 === Charge/Discharge === 526 526