Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -365,7 +365,7 @@ 365 365 366 366 (% class="box infomessage" %) 367 367 ((( 368 -**Note:** The "Allow charging"signalactivates under two independent conditions:368 +**Note:** The allow charging ышптфд closes under two independent conditions: 369 369 1) the voltage on the cells reaches the “Voltage to reset the “Ready to charge"” level and 370 370 2) the "Delay before recharging" time has passed since the opening of the allow charging contactor. 371 371 ))) ... ... @@ -372,8 +372,7 @@ 372 372 373 373 === Discharging status === 374 374 375 -* Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 376 -* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 375 +TBA 377 377 378 378 === Precharge === 379 379 ... ... @@ -431,7 +431,7 @@ 431 431 432 432 To change the parameters of the battery charge control algorithm, select the "Control → Charge" section: 433 433 434 -[[image:173 5063563460-549.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]]433 +[[image:1733322798914-813.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="327" width="800"]] 435 435 436 436 In this section: 437 437 ... ... @@ -440,7 +440,6 @@ 440 440 ** Always on – charging is always allowed; 441 441 ** On charger connected – charging is allowed when there is a signal “Charger connected”; 442 442 ** On charge request – charging is allowed when there is a signal “Charge request”; 443 -* Allow charging only when the "Ready to charge" signal i 444 444 * Current corresponding to charging – a current level to generate the "Charging current present" signal, A; 445 445 * Current corresponding to no charging – a current level to clear the "Charging current present" signal, A; 446 446 * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; ... ... @@ -521,6 +521,8 @@ 521 521 * Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 522 522 * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor; 523 523 * Minimum voltage difference to finish precharging – minimal voltage difference before and after contactors at which precharge process is meant to be finished, V; 522 +* Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 523 +* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 524 524 525 525 === Charge/Discharge === 526 526