... ... @@ -372,7 +372,8 @@
372 372  
373 373  === Discharging status ===
374 374  
375 -TBA
375 +* Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared;
376 +* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set;
376 376  
377 377  === Precharge ===
378 378  
... ... @@ -430,7 +430,7 @@
430 430  
431 431  To change the parameters of the battery charge control algorithm, select the "Control → Charge" section:
432 432  
433 -[[image:1735063563460-549.png]]
434 +[[image:1735063563460-549.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]]
434 434  
435 435  In this section:
436 436  
... ... @@ -439,6 +439,7 @@
439 439  ** Always on – charging is always allowed;
440 440  ** On charger connected – charging is allowed when there is a signal “Charger connected”;
441 441  ** On charge request – charging is allowed when there is a signal “Charge request”;
443 +* Allow charging only when the "Ready to charge" signal is set
442 442  * Current corresponding to charging – a current level to generate the "Charging current present" signal, A;
443 443  * Current corresponding to no charging – a current level to clear the "Charging current present" signal, A;
444 444  * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond;
... ... @@ -519,8 +519,6 @@
519 519  * Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond;
520 520  * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor;
521 521  * Minimum voltage difference to finish precharging – minimal voltage difference before and after contactors at which precharge process is meant to be finished, V;
522 -* Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared;
523 -* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set;
524 524  
525 525  === Charge/Discharge ===
526 526