Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 1 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -359,11 +359,21 @@ 359 359 360 360 === Charging status === 361 361 362 -TBA 362 +* Voltage to clear the “Ready to charge” – a threshold voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 363 +* Voltage to reset the “Ready to charge” – a tolerant voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 364 +* Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0. 363 363 366 +(% class="box infomessage" %) 367 +((( 368 +**Note:** The "Allow charging" signal activates under two independent conditions: 369 +1) the voltage on the cells reaches the “Voltage to reset the “Ready to charge"” level and 370 +2) the "Delay before recharging" time has passed since the opening of the allow charging contactor. 371 +))) 372 + 364 364 === Discharging status === 365 365 366 -TBA 375 +* Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 376 +* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 367 367 368 368 === Precharge === 369 369 ... ... @@ -421,7 +421,7 @@ 421 421 422 422 To change the parameters of the battery charge control algorithm, select the "Control → Charge" section: 423 423 424 -[[image:17333 22798914-813.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="327" width="800"]]434 +[[image:1735063563460-549.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]] 425 425 426 426 In this section: 427 427 ... ... @@ -430,20 +430,16 @@ 430 430 ** Always on – charging is always allowed; 431 431 ** On charger connected – charging is allowed when there is a signal “Charger connected”; 432 432 ** On charge request – charging is allowed when there is a signal “Charge request”; 443 +* Allow charging only when the "Ready to charge" signal i 433 433 * Current corresponding to charging – a current level to generate the "Charging current present" signal, A; 434 434 * Current corresponding to no charging – a current level to clear the "Charging current present" signal, A; 435 435 * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; 436 436 * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond; 448 +* Control the precharging contactor – a flag that allows control of the precharging contactor; 437 437 * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 438 438 * Custom delay: <error> – specific error delay, millisecond; 439 439 * Switch off the charging contactor on errors without delay – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging”; 440 -* Control the precharging contactor – a flag that allows control of the precharging contactor; 441 -* Voltage to clear the “Ready to charge” – a threshold voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 442 -* Voltage to reset the “Ready to charge” – a tolerant voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 443 -* Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0. 444 444 445 -Note – The allow charging contactor closes under two independent conditions: 1) the voltage on the cells reaches the “Voltage to reset the “Ready to charge"” level and 2) the "Delay before recharging" time has passed since the opening of the allow charging contactor. 446 - 447 447 === Discharge === 448 448 449 449 The device controls the discharging contactor to connect battery to the load. ... ... @@ -515,8 +515,6 @@ 515 515 * Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 516 516 * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor; 517 517 * Minimum voltage difference to finish precharging – minimal voltage difference before and after contactors at which precharge process is meant to be finished, V; 518 -* Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 519 -* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 520 520 521 521 === Charge/Discharge === 522 522
- 1735063563460-549.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +59.6 KB - Content