... ... @@ -140,7 +140,7 @@
140 140  * Minimum SOC – minimum cell SOC value for resistance calculation;
141 141  * Maximum SOC – maximum cell SOC value for resistance calculation.
142 142  
143 -The calculated resistance is accepted by the system as valid (and therefore updated) if its value is in the range from Resistance / 2 to “Maximum resistance factor” × Resistance, where "Resistance" is the nominal resistance of the cell (see [[Common settings>>doc:||anchor="HCommonsettings"]]). If the calculated resistance value is greater than the value (Maximum resistance factor × Resistance), the updated resistance value will be equal to the value (Maximum resistance factor × Resistance).
143 +The calculated resistance is accepted by the system as valid (and therefore updated) if its value is in the range from Resistance/2 to “Maximum resistance factor” × Resistance, where "Resistance" is the nominal resistance of the cell (see [[Common settings>>doc:||anchor="HCommonsettings"]]). If the calculated resistance value is greater than the value (Maximum resistance factor × Resistance), the updated resistance value will be equal to the value (Maximum resistance factor × Resistance).
144 144  
145 145  === Low SOC (signal) ===
146 146  
... ... @@ -275,6 +275,7 @@
275 275  
276 276  I,,continuous,, = Maximum CONTINUOUS charge current × K,,cc,,
277 277  
278 +
278 278  === Discharge map (PEAK & CONTINUOUS) ===
279 279  
280 280  The BMS Main 3 has an alternative algorithm for the maximum allowed discharging current based on peak and continuous battery operating modes.
... ... @@ -302,21 +302,6 @@
302 302  
303 303  I,,continuous,, = Maximum CONTINUOUS discharge current × K,,dc,,
304 304  
305 -=== Main contactor ===
306 -
307 -TBA
308 -
309 -=== Charging status ===
310 -
311 -TBA
312 -
313 -=== Discharging status ===
314 -
315 -TBA
316 -
317 -=== Precharge ===
318 -
319 -
320 320  === Charge ===
321 321  
322 322  There are two contactors that serve charging the battery: a charging contactor and an allow charging contactor. With the help of the allow charging contactor, the BMS commands the charger to start or stop charging.