Changes for page 3.3 Control

Last modified by Admin on 2025/06/19 10:56

From version 10.7
edited by Admin
on 2024/12/24 16:26
Change comment: There is no comment for this version
To version 10.6
edited by Admin
on 2024/12/24 16:25
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -140,7 +140,7 @@
140 140  * Minimum SOC – minimum cell SOC value for resistance calculation;
141 141  * Maximum SOC – maximum cell SOC value for resistance calculation.
142 142  
143 -The calculated resistance is accepted by the system as valid (and therefore updated) if its value is in the range from Resistance / 2 to “Maximum resistance factor” × Resistance, where "Resistance" is the nominal resistance of the cell (see [[Common settings>>doc:||anchor="HCommonsettings"]]). If the calculated resistance value is greater than the value (Maximum resistance factor × Resistance), the updated resistance value will be equal to the value (Maximum resistance factor × Resistance).
143 +The calculated resistance is accepted by the system as valid (and therefore updated) if its value is in the range from Resistance/2 to “Maximum resistance factor” × Resistance, where "Resistance" is the nominal resistance of the cell (see [[Common settings>>doc:||anchor="HCommonsettings"]]). If the calculated resistance value is greater than the value (Maximum resistance factor × Resistance), the updated resistance value will be equal to the value (Maximum resistance factor × Resistance).
144 144  
145 145  === Low SOC (signal) ===
146 146