... ... @@ -114,16 +114,9 @@
114 114  
115 115  The second method is used for a stepwise change in the current through the cell, while the value of the cell resistance:
116 116  
117 -{{formula}}
118 -R = \frac{U_2-U_1}{I_{stable2}-I_{stable1}}
119 -{{/formula}}
117 +R = (U,,2,,-U,,1,,) / (I,,stable2,,-I,,stable1,,) provided that | I,,stable2,,-I,,stable1,, | > 0.2 × Q,,max,,
120 120  
121 -provided that
122 122  
123 -{{formula}}
124 -|I_{stable2}-I_{stable1}| > 0.2 × Qmax
125 -{{/formula}}
126 -
127 127  (Q,,max,, is the maximum cell capacity),
128 128  
129 129  where U,,2,, is the voltage on the cell at the moment when the stabilized current I,,stable2,, is flowing through it; U,,1,, – the voltage on the cell at the moment when the stabilized current I,,stable1,, flowing through it.