Changes for page 3.3 Control
Last modified by Admin on 2025/04/09 12:14
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 4 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS MainConfiguration.WebHome1 +drafts.bms-main-3.3\. Settings.WebHome - Content
-
... ... @@ -1,14 +1,10 @@ 1 -(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Settings = 1 +1. 2 +11. 3 +111. Common settings 3 3 4 -(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 -== Control == 6 - 7 -=== Common settings === 8 - 9 9 To change the common BMS settings, select the "Control → Common settings" section: 10 10 11 -[[image:1735 054851946-552.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="105" width="800"]]7 +[[image:1733322611547-671.png]] 12 12 13 13 In this section: 14 14 ... ... @@ -16,10 +16,8 @@ 16 16 * Cell resistance – nominal (maximum) internal resistance of the cells, Ohm; 17 17 * Relax time (after charging) – a relaxation time after charging, second; 18 18 * Relax time (atfer discharging) – a relaxation time after discharging, second; 19 -* Reset parameters – a command to reset cells state of charge, capacity, and resistance; 20 -* Method of calculating the battery voltage: 21 -** Summation of cell voltages – the overall voltage is calculated as on sum of all cells in the battery; 22 -** Using voltage before contactors – the overall voltage is estimated as voltage before contactors measured by BMS. 15 +* Number of cycles – a number of charge-discharge cycles; 16 +* Reset parameters – a command to reset cells state of charge, capacity, and resistance. 23 23 24 24 The values “Capacity”, “Resistance”, “Cycles” are used to calculate the SOC of cells and the battery. 25 25 ... ... @@ -33,8 +33,11 @@ 33 33 34 34 The “Reset parameters” command is used for starting-up and adjustment of the battery. 35 35 36 -=== SOC estimation === 37 37 31 +1. 32 +11. 33 +111. SOC estimation 34 + 38 38 The BMS Main 3 device calculates the state of charge of the battery (SOC) using two algorithms: 39 39 40 40 * by open circuit voltage; ... ... @@ -44,9 +44,8 @@ 44 44 45 45 To change the estimation algorithm for calculating the battery SOC, select the "Control → SOC estimation → Algorithm" section: 46 46 44 +[[image:1733322611549-423.png]] 47 47 48 -[[image:1735056107942-306.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="141" width="800"]] 49 - 50 50 The following estimation algorithms supported: 51 51 52 52 * Voltage – by open circuit voltage; ... ... @@ -64,14 +64,13 @@ 64 64 65 65 To change the algorithm for calculating the Final SOC, select the "Control → SOC estimation → Final SOC" section: 66 66 67 -[[image:1733322611551-852.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]]63 +[[image:1733322611551-852.png]] 68 68 69 69 The following calculation methods are supported (“Final SOC”): 70 70 71 71 * Minimal SOC – the battery SOC is assumed to be the minimum SOC among the cells; 72 72 * Average SOC – the battery SOC is taken equal to the arithmetic average of the cell SOC; 73 -* Min-Max SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if any cell have 100% SOC, b) 0% if any cell have 0% SOC; 74 -* Max-Min SOC – the battery SOC is calculated based on the minimum and maximum SOC of the cells. Final SOC will be a) 100% if all cells have 100% SOC, b) 0% if all cells have 0% SOC; 69 +* Min-Max SOC – the battery SOC is taken based on the minimum and maximum SOC of the cells (recommended method). 75 75 76 76 Other parameters: 77 77 ... ... @@ -85,13 +85,15 @@ 85 85 * Coulomb counting correction (temperature) – the dependence of battery capacity on temperature; 86 86 * Coulomb counting correction (cycles) – the dependence of battery capacity on the number of charge-discharge cycles. 87 87 88 -=== SOC correction === 83 +1. 84 +11. 85 +111. SOC correction 89 89 90 -The BMS Main 3 device can recalculate the battery SOC after long-term storage or after long-term working in the case when the battery was not charged fully or discharged totally. Recalculation is done based on the tabular dependency Uocv = Uocv (SOC, t) (see [[SOC estimation>>doc:||anchor="HSOCestimation"]]).87 +The BMS Main 3 device can recalculate the battery SOC after long-term storage or after long-term working in the case when the battery was not charged fully or discharged totally. Recalculation is done based on the tabular dependency Uocv = Uocv (SOC, t) (see section** **2.3.2). 91 91 92 92 To configure parameters for periodically correcting the battery state of charge, select the "Control → SOC correction" section: 93 93 94 -[[image:1733322624656-766.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="121" width="800"]]91 +[[image:1733322624656-766.png]] 95 95 96 96 In this section: 97 97 ... ... @@ -102,24 +102,21 @@ 102 102 * Ignore the linear zone – a flag to ignore linear SOC zone while correction (recommended to be unset); 103 103 * Last correction timestamp – time when last correction was made. 104 104 105 -=== Resistance estimation === 106 106 103 +1. 104 +11. 105 +111. Resistance estimation 106 + 107 107 Calculation of the resistance of cells is carried out in two ways. The first method is used when the battery passes from a relaxation state to a charge or discharge state, wherein the cell resistance value 108 108 109 -{{formula fontSize="NORMAL" imageType="PNG"}} 110 -R = \frac{U-U_{ocv}}{I_{stable}} 111 -{{/formula}} 109 +R = (U-U,,ocv,,) / I,,stable,,, 112 112 113 -where U —the cell voltage measured in the charge or discharge state, V; U,,ocv,,—cell voltage measured in the state of relaxation (before switching to the state of charge or discharge); I,,stable,,—stabilized current through the cell in the state of charge or discharge.111 +where U is the cell voltage measured in the charge or discharge state, V; U,,ocv,, is the cell voltage measured in the state of relaxation (before switching to the state of charge or discharge); I,,stable,, – stabilized current through the cell in the state of charge or discharge. 114 114 115 115 The second method is used for a stepwise change in the current through the cell, while the value of the cell resistance: 116 116 117 117 R = (U,,2,,-U,,1,,) / (I,,stable2,,-I,,stable1,,) provided that | I,,stable2,,-I,,stable1,, | > 0.2 × Q,,max,, 118 118 119 -{{formula}} 120 -R = frac\{U_2-U_1}{I_{stable2}-I_{stable1}} 121 -{{/formula}} 122 - 123 123 (Q,,max,, is the maximum cell capacity), 124 124 125 125 where U,,2,, is the voltage on the cell at the moment when the stabilized current I,,stable2,, is flowing through it; U,,1,, – the voltage on the cell at the moment when the stabilized current I,,stable1,, flowing through it. ... ... @@ -128,7 +128,7 @@ 128 128 129 129 To change parameters of the algorithm for calculating the cell resistance, select the "Control → Resistance estimation" section: 130 130 131 -[[image:1733322624659-473.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="108" width="800"]]125 +[[image:1733322624659-473.png]] 132 132 133 133 In this section: 134 134 ... ... @@ -138,13 +138,16 @@ 138 138 * Minimum SOC – minimum cell SOC value for resistance calculation; 139 139 * Maximum SOC – maximum cell SOC value for resistance calculation. 140 140 141 -The calculated resistance is accepted by the system as valid (and therefore updated) if its value is in the range from Resistance/2 to “Maximum resistance factor” × Resistance, where "Resistance" is the nominal resistance of the cell (see [[Commonsettings>>doc:||anchor="HCommonsettings"]]). If the calculated resistance value is greater than the value (Maximum resistance factor × Resistance), the updated resistance value will be equal to the value (Maximum resistance factor × Resistance).135 +The calculated resistance is accepted by the system as valid (and therefore updated) if its value is in the range from Resistance/2 to “Maximum resistance factor” × Resistance, where "Resistance" is the nominal resistance of the cell (see section 2.3.1). If the calculated resistance value is greater than the value (Maximum resistance factor × Resistance), the updated resistance value will be equal to the value (Maximum resistance factor × Resistance). 142 142 143 -=== Low SOC (signal) === 144 144 138 +1. 139 +11. 140 +111. Low SOC (signal) 141 + 145 145 To change the parameters of the generation a signal about low battery level, select the "Control → Low SOC (signal)" section: 146 146 147 -[[image:1733322624660-513.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="116" width="800"]]144 +[[image:1733322624660-513.png]] 148 148 149 149 In this section: 150 150 ... ... @@ -165,11 +165,14 @@ 165 165 166 166 The "Low SOC signal" is indicative and can be output to a discrete output or a power switch. 167 167 168 -=== High charging current (signal) === 169 169 166 +1. 167 +11. 168 +111. High charging current (signal) 169 + 170 170 To change the parameters of the generation high-current signal, select the "Control → High charging current (signal)" section: 171 171 172 -[[image:1733322624661-915.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="107" width="800"]]172 +[[image:1733322624661-915.png]] 173 173 174 174 In this section: 175 175 ... ... @@ -190,8 +190,11 @@ 190 190 191 191 The "High charging current" signal is indicative and can be output to a discrete output or a power switch. 192 192 193 -=== Charge map === 194 194 194 +1. 195 +11. 196 +111. Charge map 197 + 195 195 The BMS Main 3 device calculates the maximum allowable charge current values in respect to SOC, battery temperature, contactor temperature and cell voltage. 196 196 197 197 Calculated current values are sent to a charger or an intellectual load over the CAN bus. External devices based on received data provide correct battery operation. ... ... @@ -198,7 +198,7 @@ 198 198 199 199 To configure parameters for determining the charge current limit, select the "Control → Charge map" section: 200 200 201 -[[image:1733322637793-171.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="177" width="800"]]204 +[[image:1733322637793-171.png]] 202 202 203 203 In this section: 204 204 ... ... @@ -218,8 +218,11 @@ 218 218 219 219 Charging current limit = Maximum charging current × Kcs × Kcc × Kcv × Kct 220 220 221 -=== Discharge map === 222 222 225 +1. 226 +11. 227 +111. Discharge map 228 + 223 223 The BMS Main 3 device calculates the maximum allowable discharge current values in respect to SOC, battery temperature, contactor temperature and cell voltage. 224 224 225 225 Calculated current values are sent to a charger or an intellectual load over the CAN bus. ... ... @@ -226,7 +226,7 @@ 226 226 227 227 To configure parameters for determining the discharge current limit, select the "Control → Discharge map" section: 228 228 229 -[[image:1733322637795-310.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="178" width="800"]]235 +[[image:1733322637795-310.png]] 230 230 231 231 In this section: 232 232 ... ... @@ -246,13 +246,16 @@ 246 246 247 247 Discharging current limit = Maximum discharging current × Kds × Kdc × Kdv × Kdt 248 248 249 -=== Charge map (PEAK & CONTINUOUS) === 250 250 256 +1. 257 +11. 258 +111. Charge map (PEAK & CONTINUOUS) 259 + 251 251 The BMS Main 3 has an alternative algorithm for the maximum allowed charging current based on peak and continuous battery operating modes. 252 252 253 253 To configure parameters for determining the charge current limit, select the "Control → Charge map (PEAK & CONTINUOUS)" section: 254 254 255 -[[image:1733322637796-187.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="145" width="800"]]264 +[[image:1733322637796-187.png]] 256 256 257 257 In this section: 258 258 ... ... @@ -267,7 +267,7 @@ 267 267 268 268 The maximum charging current value equals to the peak or continuous current according to the following diagram: 269 269 270 -[[image:1733322717451-608.png ||data-xwiki-image-style-alignment="center"]]279 +[[image:1733322717451-608.png]] 271 271 272 272 I,,peak,, = Maximum PEAK charge current × K,,cp,, 273 273 ... ... @@ -274,13 +274,15 @@ 274 274 I,,continuous,, = Maximum CONTINUOUS charge current × K,,cc,, 275 275 276 276 277 -=== Discharge map (PEAK & CONTINUOUS) === 286 +1. 287 +11. 288 +111. Discharge map (PEAK & CONTINUOUS) 278 278 279 279 The BMS Main 3 has an alternative algorithm for the maximum allowed discharging current based on peak and continuous battery operating modes. 280 280 281 281 To configure parameters for determining the discharge current limit, select the "Control → Discharge map (PEAK & CONTINUOUS)" section: 282 282 283 -[[image:1733322735595-661.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="145" width="800"]]294 +[[image:1733322735595-661.png]] 284 284 285 285 In this section: 286 286 ... ... @@ -295,14 +295,17 @@ 295 295 296 296 The maximum discharging current value equals to the peak or continuous current according to following diagram: 297 297 298 -[[image:1733322753429-968.png ||data-xwiki-image-style-alignment="center"]]309 +[[image:1733322753429-968.png]] 299 299 300 300 I,,peak,, = Maximum PEAK discharge current × K,,dp,, 301 301 302 302 I,,continuous,, = Maximum CONTINUOUS discharge current × K,,dc,, 303 303 304 -=== Charge === 305 305 316 +1. 317 +11. 318 +111. Charge 319 + 306 306 There are two contactors that serve charging the battery: a charging contactor and an allow charging contactor. With the help of the allow charging contactor, the BMS commands the charger to start or stop charging. 307 307 308 308 The device supports three charge control algorithms: ... ... @@ -353,7 +353,7 @@ 353 353 354 354 To change the parameters of the battery charge control algorithm, select the "Control → Charge" section: 355 355 356 -[[image:1733322798914-813.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="327" width="800"]]370 +[[image:1733322798914-813.png]] 357 357 358 358 In this section: 359 359 ... ... @@ -376,7 +376,9 @@ 376 376 377 377 Note – The allow charging contactor closes under two independent conditions: 1) the voltage on the cells reaches the “Voltage to reset the “Ready to charge"” level and 2) the "Delay before recharging" time has passed since the opening of the allow charging contactor. 378 378 379 -=== Discharge === 393 +1. 394 +11. 395 +111. Discharge 380 380 381 381 The device controls the discharging contactor to connect battery to the load. 382 382 ... ... @@ -428,8 +428,10 @@ 428 428 429 429 To change the parameters of the battery discharge control algorithm, select the "Control → Discharge" section: 430 430 431 -[[image:1 733323750262-841.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="360"width="800"]]447 +[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png||alt="A screenshot of a computer 432 432 449 +Description automatically generated"]] 450 + 433 433 In this section: 434 434 435 435 * Enable – a flag to activate the discharge control; ... ... @@ -450,20 +450,26 @@ 450 450 * Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 451 451 * Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 452 452 453 -=== Charge/Discharge === 454 454 472 +1. 473 +11. 474 +111. Charge/Discharge 475 + 455 455 The BMS Main 3 device can control the charging/discharging contactor, which combines algorithms of charging and discharging contactor. It behaves as a charging contactor when “Charge request” or “Charger connected” is set, otherwise – as a discharging contactor. 456 456 457 457 The charging/discharging contactor control is configured in the “Control – Charge/Discharge” section: 458 458 459 -[[image:1733322827919-875.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="85" width="800"]]480 +[[image:1733322827919-875.png]] 460 460 461 461 In this section: 462 462 463 463 * Enable – a flag to enable the charge/discharge controller. 464 464 465 -=== Discharge (AUX) === 466 466 487 +1. 488 +11. 489 +111. Discharge (AUX) 490 + 467 467 The BMS Main 3 device can control the power supply of external equipment using the auxiliary (AUX) discharging contactor. An example of external equipment can be an inverter that converts DC to AC to power a service laptop and other devices. 468 468 469 469 The power supply circuit of the external equipment using the auxiliary (AUX) discharging contactor is independent of the battery load circuit. The closing and opening of the auxiliary (AUX) discharging contactor is performed according to its program. ... ... @@ -476,7 +476,7 @@ 476 476 477 477 To change the parameters of the powering of external equipment, select the "Control → Discharge (AUX)" section: 478 478 479 -[[image:1733322827920-878.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="130" width="800"]]503 +[[image:1733322827920-878.png]] 480 480 481 481 In this section: 482 482 ... ... @@ -489,7 +489,9 @@ 489 489 * Maximum voltage – maximum battery voltage, V; 490 490 * Switch off the discharging (AUX) contactor on errors – the auxiliary (AUX) discharging contactor opens if the following errors occur: Undervoltage, Overcurrent, High temperature (DCH), Short circuit, Critical error. 491 491 492 -=== Main contactor === 516 +1. 517 +11. 518 +111. Main contactor 493 493 494 494 The BMS Main 3 device controls the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in case of sealing of the charging or discharging contactors. 495 495 ... ... @@ -531,7 +531,7 @@ 531 531 532 532 To change the parameters of the main contactor, select the "Control → Main contactor" section: 533 533 534 -[[image:1733322872744-536.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="105" width="800"]]560 +[[image:1733322872744-536.png]] 535 535 536 536 In this section: 537 537 ... ... @@ -544,7 +544,9 @@ 544 544 * Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, s; 545 545 * Keep the contactor open until the device is restarted – a flag for keeping the main contactor open until the system is reset. 546 546 547 -=== Cell balancing === 573 +1. 574 +11. 575 +111. Cell balancing 548 548 549 549 Balancing makes the voltage of all cells equal to the minimum cell voltage. 550 550 ... ... @@ -570,7 +570,7 @@ 570 570 571 571 To change the cell balancing parameters, select the "Control → Cell balancing" section: 572 572 573 -[[image:1733322883460-118.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="114" width="800"]]601 +[[image:1733322883460-118.png]] 574 574 575 575 In this section: 576 576 ... ... @@ -580,7 +580,7 @@ 580 580 ** Balance on charge or relaxed - balancing is performed while and after the charging and in the relaxed state (in “Charge ON”, “Charge OFF”, “Relaxed (after charging)” and “Relaxed (after discharging)” states); 581 581 ** Balance always – balancing is always performed regardless the battery state; 582 582 583 -[[image:1733322883462-975.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="74" width="600"]]611 +[[image:1733322883462-975.png]] 584 584 585 585 * Minimum cell voltage to start balancing, V; 586 586 * Voltage deviation to start balancing; ... ... @@ -587,8 +587,11 @@ 587 587 * Voltage deviation to stop balancing; 588 588 * Command to discharge all cells – a flag to force the balancing of all cells. 589 589 590 -=== Series balancing === 591 591 619 +1. 620 +11. 621 +111. Series balancing 622 + 592 592 The BMS Main 3 device supports work with two independent (galvanically unrelated) cell series. To monitor the status of two series, two current sensors are used. A series of cells must be equivalent: they must have the same number of cells and the same capacity. 593 593 594 594 Since the series of cells can operate at different loads, they must be balanced. For this, the BMS Main 3 provides two signals to power switches: “Balancing series 1” and “Balancing series 2”, as well as a combined algorithm that considers both the voltage of each series and the charge that these series gave load. The “Balancing series 1” and “Balancing series 2” signals are used to connect high-power balancing resistors in parallel with cell series 1 and 2. ... ... @@ -602,7 +602,7 @@ 602 602 603 603 To change the series balancing parameters, select the "Control → Series balancing" section: 604 604 605 -[[image:1733322892811-410.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="126" width="800"]]636 +[[image:1733322892811-410.png]] 606 606 607 607 In this section: 608 608 ... ... @@ -612,10 +612,13 @@ 612 612 * Balancing threshold, V; 613 613 * Coulomb threshold – the difference of the charges Qthr, given by a series of cells, above which balancing to be started, Ah; 614 614 * Period – a period to reset of charge counters for each series (to avoid accumulation of error), second; 615 -* Do not sum series voltages – a flag to disable the summing of series voltages. 3646 +* Do not sum series voltages – a flag to disable the summing of series voltages. 616 616 617 -=== Power down === 618 618 649 +1. 650 +11. 651 +111. Power down 652 + 619 619 The BMS Main 3 device can shut down itself if the battery voltage is low or the battery is idle for a long time. 620 620 621 621 Shutting down the battery system is performed according to the following conditions: ... ... @@ -627,7 +627,7 @@ 627 627 628 628 To change the parameters of the power down control, select the "Control → Power down" section: 629 629 630 -[[image:1733322892813-562.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="103" width="800"]]664 +[[image:1733322892813-562.png]] 631 631 632 632 In this section: 633 633 ... ... @@ -637,11 +637,13 @@ 637 637 * Power down if KEYRUN and CHARGE_ON are cleared – a flag to power down the device if KEYRUN and CHARGE_ON signals are cleared; 638 638 * Delay before setting the internal power down signal – a delay before turning off the device power when removing KEYRUN and CHARGE_ON or receiving the “Power down request” command, ms. 639 639 640 -=== Heater === 674 +1. 675 +11. 676 +111. Heater 641 641 642 642 To change the parameters of the heater control algorithm, select the "Control → Heater" section: 643 643 644 -[[image:1733322901923-144.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="108" width="800"]]680 +[[image:1733322901923-144.png]] 645 645 646 646 In this section: 647 647 ... ... @@ -664,11 +664,14 @@ 664 664 665 665 If there is the "Heater" signal, the heater contactor closes and/or a signal is output to the corresponding digital output. 666 666 667 -=== Cooler === 668 668 704 +1. 705 +11. 706 +111. Cooler 707 + 669 669 To change the parameters of the cooler control algorithm, select the "Control → Cooler" section: 670 670 671 -[[image:1733322901924-962.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="107" width="800"]]710 +[[image:1733322901924-962.png]] 672 672 673 673 In this section: 674 674 ... ... @@ -691,13 +691,16 @@ 691 691 692 692 If there is the "Cooler" signal, the cooler contactor closes and/or a signal is output to the corresponding digital output. 693 693 694 -=== High voltage === 695 695 734 +1. 735 +11. 736 +111. High voltage 737 + 696 696 The BMS Main 3 device has an ability to measure high voltages before and after contactors. 697 697 698 698 To change the parameters of high voltage fault, select the "Control → High voltage" section: 699 699 700 -[[image:1733322914683-203.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="87" width="800"]]742 +[[image:1733322914683-203.png]] 701 701 702 702 In this section: 703 703 ... ... @@ -709,8 +709,11 @@ 709 709 710 710 **If there is the “High voltage fault”, the “Critical error” is generated and all contactors open.** 711 711 712 -=== Cell analysis === 713 713 755 +1. 756 +11. 757 +111. Cell analysis 758 + 714 714 The battery discharge characteristic – the dependence Uocv = Uocv(DOD) – is used to determine the tabular dependence Uocv = Uocv(SOC, t°C), which is necessary for calculating the battery charge level. 715 715 716 716 The BMS Main 3 device can automatically determine the battery discharge characteristic. ... ... @@ -722,7 +722,7 @@ 722 722 723 723 To configure parameters for determining the discharge characteristic of the battery, select the "Control → Cell analysis" section: 724 724 725 -[[image:1733322914685-558.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="107" width="800"]]770 +[[image:1733322914685-558.png]] 726 726 727 727 In this section: 728 728
- 1733323750262-841.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -69.6 KB - Content
- 1735054851946-552.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -22.9 KB - Content
- 1735056052237-170.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -32.1 KB - Content
- 1735056107942-306.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -33.0 KB - Content