... ... @@ -106,19 +106,26 @@ 106 106 107 107 Calculation of the resistance of cells is carried out in two ways. The first method is used when the battery passes from a relaxation state to a charge or discharge state, wherein the cell resistance value 108 108 109 -R = (U-U,,ocv,,) / I,,stable,,, 109 +{{formula fontSize="SMALL" imageType="PNG"}} 110 +R = \frac{U-U_{ocv}}{I_{stable}} 111 +{{/formula}} 110 110 113 +where U — the cell voltage measured in the charge or discharge state, V; U,,ocv,, — cell voltage measured in the state of relaxation (before switching to the state of charge or discharge); I,,stable,, — stabilized current through the cell in the state of charge or discharge. 111 111 112 -where U is the cell voltage measured in the charge or discharge state, V; U,,ocv,, is the cell voltage measured in the state of relaxation (before switching to the state of charge or discharge); I,,stable,, – stabilized current through the cell in the state of charge or discharge. 113 - 114 114 The second method is used for a stepwise change in the current through the cell, while the value of the cell resistance: 115 115 116 -R = (U,,2,,-U,,1,,) / (I,,stable2,,-I,,stable1,,) provided that | I,,stable2,,-I,,stable1,, | > 0.2 × Q,,max,, 117 +{{formula fontSize="SMALL"}} 118 +R = \frac{U_2-U_1}{I_{stable2}-I_{stable1}} 119 +{{/formula}} 117 117 118 - (Q,,max,,isthe maximum cell capacity),121 +provided that 119 119 120 -where U,,2,, is the voltage on the cell at the moment when the stabilized current I,,stable2,, is flowing through it; U,,1,, – the voltage on the cell at the moment when the stabilized current I,,stable1,, flowing through it. 123 +{{formula fontSize="SMALL"}} 124 +| I_{stable2}-I_{stable1} | > 0.2 × Qmax 125 +{{/formula}} 121 121 127 +where Q,,max,, — the maximum cell capacity,U,,2,, — voltage on the cell at the moment when the stabilized current I,,stable2,, is flowing through it; U,,1,, — the voltage on the cell at the moment when the stabilized current I,,stable1,, flowing through it. 128 + 122 122 The stabilized current I,,stable,, = I, if during the stabilization time the instantaneous current I is in the range from 0.95 × I to 1.05 × I. 123 123 124 124 To change parameters of the algorithm for calculating the cell resistance, select the "Control → Resistance estimation" section: ... ... @@ -133,7 +133,7 @@ 133 133 * Minimum SOC – minimum cell SOC value for resistance calculation; 134 134 * Maximum SOC – maximum cell SOC value for resistance calculation. 135 135 136 -The calculated resistance is accepted by the system as valid (and therefore updated) if its value is in the range from Resistance/2 to “Maximum resistance factor” × Resistance, where "Resistance" is the nominal resistance of the cell (see [[Common settings>>doc:||anchor="HCommonsettings"]]). If the calculated resistance value is greater than the value (Maximum resistance factor × Resistance), the updated resistance value will be equal to the value (Maximum resistance factor × Resistance). 143 +The calculated resistance is accepted by the system as valid (and therefore updated) if its value is in the range from Resistance / 2 to “Maximum resistance factor” × Resistance, where "Resistance" is the nominal resistance of the cell (see [[Common settings>>doc:||anchor="HCommonsettings"]]). If the calculated resistance value is greater than the value (Maximum resistance factor × Resistance), the updated resistance value will be equal to the value (Maximum resistance factor × Resistance). 137 137 138 138 === Low SOC (signal) === 139 139 ... ... @@ -268,7 +268,6 @@ 268 268 269 269 I,,continuous,, = Maximum CONTINUOUS charge current × K,,cc,, 270 270 271 - 272 272 === Discharge map (PEAK & CONTINUOUS) === 273 273 274 274 The BMS Main 3 has an alternative algorithm for the maximum allowed discharging current based on peak and continuous battery operating modes. ... ... @@ -296,6 +296,83 @@ 296 296 297 297 I,,continuous,, = Maximum CONTINUOUS discharge current × K,,dc,, 298 298 305 +=== Main contactor === 306 + 307 +The BMS Main 3 device controls the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in case of sealing of the charging or discharging contactors. 308 + 309 +The Main contactor algorithm supports the following modes: 310 + 311 +* Always on; 312 +* Automatic; 313 +* On demand. 314 + 315 +In “Always on” mode main contactor closes if all the following is true: 316 + 317 +* Charging contactor is open; 318 +* Discharging contactor is open; 319 +* There are no errors from the list below: 320 +** Overcurrent; 321 +** Undervoltage; 322 +** Overvoltage; 323 +** High temperature (CH); 324 +** High temperature (DCH); 325 +** Unallowable charging; 326 +** Critical error. 327 + 328 +In “Always on” mode main contactor opens if all the following is true: 329 + 330 +* Charging contactor is open; 331 +* Discharging contactor is open; 332 +* There is an error from the list below: 333 +** Overcurrent; 334 +** Undervoltage; 335 +** Overvoltage; 336 +** High temperature (CH); 337 +** High temperature (DCH); 338 +** Unallowable charging; 339 +** Critical error. 340 + 341 +In “Automatic” mode, the main contactor closes by internal charging and discharging algorithms at the same time with Precharging, Charging and Discharging contactors. 342 + 343 +In “On demand” mode, the main contactor closes by external the “Close Main contactor” request. 344 + 345 +To change the parameters of the main contactor, select the "Control → Main contactor" section: 346 + 347 +[[image:1733322872744-536.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="105" width="800"]] 348 + 349 +In this section: 350 + 351 +* Enable – a flag to enable the main contactor control; 352 +* Algorithm – main contactor control algorithm: 353 +** Always on – contactor is always closed; 354 +** Automatic – contactor closes by internal charge and discharge algorithms; 355 +** On demand – contactor is closed by an external request; 356 +* Time to keep the contactor closed before closing the others – a time for other contactors to be open after the main contactor is closed; 357 +* Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, s; 358 +* Keep the contactor open until the device is restarted – a flag for keeping the main contactor open until the system is reset. 359 + 360 +=== Charging status === 361 + 362 +* Voltage to clear the “Ready to charge” – a threshold voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 363 +* Voltage to reset the “Ready to charge” – a tolerant voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 364 +* Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0. 365 + 366 +(% class="box infomessage" %) 367 +((( 368 +**Note:** The "Allow charging" signal activates under two independent conditions: 369 +1) the voltage on the cells reaches the “Voltage to reset the “Ready to charge"” level and 370 +2) the "Delay before recharging" time has passed since the opening of the allow charging contactor. 371 +))) 372 + 373 +=== Discharging status === 374 + 375 +* Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 376 +* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 377 + 378 +=== Precharge === 379 + 380 +TBA 381 + 299 299 === Charge === 300 300 301 301 There are two contactors that serve charging the battery: a charging contactor and an allow charging contactor. With the help of the allow charging contactor, the BMS commands the charger to start or stop charging. ... ... @@ -348,7 +348,7 @@ 348 348 349 349 To change the parameters of the battery charge control algorithm, select the "Control → Charge" section: 350 350 351 -[[image:17333 22798914-813.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="327" width="800"]]434 +[[image:1735063563460-549.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="262" width="800"]] 352 352 353 353 In this section: 354 354 ... ... @@ -357,20 +357,16 @@ 357 357 ** Always on – charging is always allowed; 358 358 ** On charger connected – charging is allowed when there is a signal “Charger connected”; 359 359 ** On charge request – charging is allowed when there is a signal “Charge request”; 443 +* Allow charging only when the "Ready to charge" signal is set 360 360 * Current corresponding to charging – a current level to generate the "Charging current present" signal, A; 361 361 * Current corresponding to no charging – a current level to clear the "Charging current present" signal, A; 362 362 * Delay before starting charging – a time delay T,,on,, before closing the charging contactor and the allow charging contactor, millisecond; 363 363 * Delay before stopping charging – a time delay T,,off,, before opening the charging contactor, millisecond; 448 +* Control the precharging contactor – a flag that allows control of the precharging contactor; 364 364 * Use custom delays before stopping charging (on errors) – a flag to enable manual settings of time delays T,,off,, for specific errors; 365 365 * Custom delay: <error> – specific error delay, millisecond; 366 366 * Switch off the charging contactor on errors without delay – a flag to protectively open the charging contactor without a delay. In the opposite case, when an error is detected, the charging contactor opens always with the delay “Delay before stopping charging”; 367 -* Control the precharging contactor – a flag that allows control of the precharging contactor; 368 -* Voltage to clear the “Ready to charge” – a threshold voltage level on the cell, V; if the voltage of any cell is above this level, the “Ready to charge” (hence, the “Allow charging”) signal is cleared; 369 -* Voltage to reset the “Ready to charge” – a tolerant voltage level on the cell, V; if all cell voltages are below the tolerant level, the “Ready to charge” (hence, the “Allow charging”) signal is set; 370 -* Delay before recharging – a time after which the previously opened the allow charging contactor closes again, minute; to disable the operation by timeout set "Delay before recharging" to 0. 371 371 372 -Note – The allow charging contactor closes under two independent conditions: 1) the voltage on the cells reaches the “Voltage to reset the “Ready to charge"” level and 2) the "Delay before recharging" time has passed since the opening of the allow charging contactor. 373 - 374 374 === Discharge === 375 375 376 376 The device controls the discharging contactor to connect battery to the load. ... ... @@ -442,8 +442,6 @@ 442 442 * Precharge time – a duration of closing the precharge contactor before closing the discharging contactor, millisecond; 443 443 * Check voltages before and after contactors to finish precharging – a flag to check the voltages before and after contactors to ensure that precharge process has finished and it is allowed to close the discharging contactor; 444 444 * Minimum voltage difference to finish precharging – minimal voltage difference before and after contactors at which precharge process is meant to be finished, V; 445 -* Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared; 446 -* Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set; 447 447 448 448 === Charge/Discharge === 449 449 ... ... @@ -484,61 +484,6 @@ 484 484 * Maximum voltage – maximum battery voltage, V; 485 485 * Switch off the discharging (AUX) contactor on errors – the auxiliary (AUX) discharging contactor opens if the following errors occur: Undervoltage, Overcurrent, High temperature (DCH), Short circuit, Critical error. 486 486 487 -=== Main contactor === 488 - 489 -The BMS Main 3 device controls the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in case of sealing of the charging or discharging contactors. 490 - 491 -The Main contactor algorithm supports the following modes: 492 - 493 -* Always on; 494 -* Automatic; 495 -* On demand. 496 - 497 -In “Always on” mode main contactor closes if all the following is true: 498 - 499 -* Charging contactor is open; 500 -* Discharging contactor is open; 501 -* There are no errors from the list below: 502 -** Overcurrent; 503 -** Undervoltage; 504 -** Overvoltage; 505 -** High temperature (CH); 506 -** High temperature (DCH); 507 -** Unallowable charging; 508 -** Critical error. 509 - 510 -In “Always on” mode main contactor opens if all the following is true: 511 - 512 -* Charging contactor is open; 513 -* Discharging contactor is open; 514 -* There is an error from the list below: 515 -** Overcurrent; 516 -** Undervoltage; 517 -** Overvoltage; 518 -** High temperature (CH); 519 -** High temperature (DCH); 520 -** Unallowable charging; 521 -** Critical error. 522 - 523 -In “Automatic” mode, the main contactor closes by internal charging and discharging algorithms at the same time with Precharging, Charging and Discharging contactors. 524 - 525 -In “On demand” mode, the main contactor closes by external the “Close Main contactor” request. 526 - 527 -To change the parameters of the main contactor, select the "Control → Main contactor" section: 528 - 529 -[[image:1733322872744-536.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="105" width="800"]] 530 - 531 -In this section: 532 - 533 -* Enable – a flag to enable the main contactor control; 534 -* Algorithm – main contactor control algorithm: 535 -** Always on – contactor is always closed; 536 -** Automatic – contactor closes by internal charge and discharge algorithms; 537 -** On demand – contactor is closed by an external request; 538 -* Time to keep the contactor closed before closing the others – a time for other contactors to be open after the main contactor is closed; 539 -* Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, s; 540 -* Keep the contactor open until the device is restarted – a flag for keeping the main contactor open until the system is reset. 541 - 542 542 === Cell balancing === 543 543 544 544 Balancing makes the voltage of all cells equal to the minimum cell voltage.
- 1735063563460-549.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +59.6 KB - Content