... ... @@ -1,10 +1,14 @@
1 -1.
2 -11.
3 -111. Common settings
1 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 += Settings =
4 4  
4 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 +== Control ==
6 +
7 +=== Common settings ===
8 +
5 5  To change the common BMS settings, select the "Control → Common settings" section:
6 6  
7 -[[image:1733322611547-671.png]]
11 +[[image:1735054851946-552.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="105" width="800"]]
8 8  
9 9  In this section:
10 10  
... ... @@ -12,8 +12,10 @@
12 12  * Cell resistance – nominal (maximum) internal resistance of the cells, Ohm;
13 13  * Relax time (after charging) – a relaxation time after charging, second;
14 14  * Relax time (atfer discharging) – a relaxation time after discharging, second;
15 -* Number of cycles – a number of charge-discharge cycles;
16 -* Reset parameters – a command to reset cells state of charge, capacity, and resistance.
19 +* Reset parameters – a command to reset cells state of charge, capacity, and resistance;
20 +* Method of calculating the battery voltage:
21 +** Summation of cell voltages – the overall voltage is calculated as on sum of all cells in the battery;
22 +** Using voltage before contactors – the overall voltage is estimated as voltage before contactors measured by BMS.
17 17  
18 18  The values “Capacity”, “Resistance”, “Cycles” are used to calculate the SOC of cells and the battery.
19 19  
... ... @@ -27,11 +27,8 @@
27 27  
28 28  The “Reset parameters” command is used for starting-up and adjustment of the battery.
29 29  
36 +=== SOC estimation ===
30 30  
31 -1.
32 -11.
33 -111. SOC estimation
34 -
35 35  The BMS Main 3 device calculates the state of charge of the battery (SOC) using two algorithms:
36 36  
37 37  * by open circuit voltage;
... ... @@ -41,8 +41,9 @@
41 41  
42 42  To change the estimation algorithm for calculating the battery SOC, select the "Control → SOC estimation → Algorithm" section:
43 43  
44 -[[image:1733322611549-423.png]]
45 45  
48 +[[image:1735056107942-306.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="141" width="800"]]
49 +
46 46  The following estimation algorithms supported:
47 47  
48 48  * Voltage – by open circuit voltage;
... ... @@ -60,7 +60,7 @@
60 60  
61 61  To change the algorithm for calculating the Final SOC, select the "Control → SOC estimation → Final SOC" section:
62 62  
63 -[[image:1733322611551-852.png]]
67 +[[image:1733322611551-852.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]]
64 64  
65 65  The following calculation methods are supported (“Final SOC”):
66 66  
... ... @@ -67,6 +67,7 @@
67 67  * Minimal SOC – the battery SOC is assumed to be the minimum SOC among the cells;
68 68  * Average SOC – the battery SOC is taken equal to the arithmetic average of the cell SOC;
69 69  * Min-Max SOC – the battery SOC is taken based on the minimum and maximum SOC of the cells (recommended method).
74 +* Min-Max SOC – the battery SOC is taken based on the minimum and maximum SOC of the cells (recommended method).
70 70  
71 71  Other parameters:
72 72  
... ... @@ -80,15 +80,13 @@
80 80  * Coulomb counting correction (temperature) – the dependence of battery capacity on temperature;
81 81  * Coulomb counting correction (cycles) – the dependence of battery capacity on the number of charge-discharge cycles.
82 82  
83 -1.
84 -11.
85 -111. SOC correction
88 +=== SOC correction ===
86 86  
87 -The BMS Main 3 device can recalculate the battery SOC after long-term storage or after long-term working in the case when the battery was not charged fully or discharged totally. Recalculation is done based on the tabular dependency Uocv = Uocv (SOC, t) (see section** **2.3.2).
90 +The BMS Main 3 device can recalculate the battery SOC after long-term storage or after long-term working in the case when the battery was not charged fully or discharged totally. Recalculation is done based on the tabular dependency Uocv = Uocv (SOC, t) (see [[SOC estimation>>doc:||anchor="HSOCestimation"]]).
88 88  
89 89  To configure parameters for periodically correcting the battery state of charge, select the "Control → SOC correction" section:
90 90  
91 -[[image:1733322624656-766.png]]
94 +[[image:1733322624656-766.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="121" width="800"]]
92 92  
93 93  In this section:
94 94  
... ... @@ -99,11 +99,8 @@
99 99  * Ignore the linear zone – a flag to ignore linear SOC zone while correction (recommended to be unset);
100 100  * Last correction timestamp – time when last correction was made.
101 101  
105 +=== Resistance estimation ===
102 102  
103 -1.
104 -11.
105 -111. Resistance estimation
106 -
107 107  Calculation of the resistance of cells is carried out in two ways. The first method is used when the battery passes from a relaxation state to a charge or discharge state, wherein the cell resistance value
108 108  
109 109  R = (U-U,,ocv,,) / I,,stable,,,
... ... @@ -122,7 +122,7 @@
122 122  
123 123  To change parameters of the algorithm for calculating the cell resistance, select the "Control → Resistance estimation" section:
124 124  
125 -[[image:1733322624659-473.png]]
125 +[[image:1733322624659-473.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="108" width="800"]]
126 126  
127 127  In this section:
128 128  
... ... @@ -132,16 +132,13 @@
132 132  * Minimum SOC – minimum cell SOC value for resistance calculation;
133 133  * Maximum SOC – maximum cell SOC value for resistance calculation.
134 134  
135 -The calculated resistance is accepted by the system as valid (and therefore updated) if its value is in the range from Resistance/2 to “Maximum resistance factor” × Resistance, where "Resistance" is the nominal resistance of the cell (see section 2.3.1). If the calculated resistance value is greater than the value (Maximum resistance factor × Resistance), the updated resistance value will be equal to the value (Maximum resistance factor × Resistance).
135 +The calculated resistance is accepted by the system as valid (and therefore updated) if its value is in the range from Resistance/2 to “Maximum resistance factor” × Resistance, where "Resistance" is the nominal resistance of the cell (see [[Common settings>>doc:||anchor="HCommonsettings"]]). If the calculated resistance value is greater than the value (Maximum resistance factor × Resistance), the updated resistance value will be equal to the value (Maximum resistance factor × Resistance).
136 136  
137 +=== Low SOC (signal) ===
137 137  
138 -1.
139 -11.
140 -111. Low SOC (signal)
141 -
142 142  To change the parameters of the generation a signal about low battery level, select the "Control → Low SOC (signal)" section:
143 143  
144 -[[image:1733322624660-513.png]]
141 +[[image:1733322624660-513.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="116" width="800"]]
145 145  
146 146  In this section:
147 147  
... ... @@ -162,14 +162,11 @@
162 162  
163 163  The "Low SOC signal" is indicative and can be output to a discrete output or a power switch.
164 164  
162 +=== High charging current (signal) ===
165 165  
166 -1.
167 -11.
168 -111. High charging current (signal)
169 -
170 170  To change the parameters of the generation high-current signal, select the "Control → High charging current (signal)" section:
171 171  
172 -[[image:1733322624661-915.png]]
166 +[[image:1733322624661-915.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="107" width="800"]]
173 173  
174 174  In this section:
175 175  
... ... @@ -190,11 +190,8 @@
190 190  
191 191  The "High charging current" signal is indicative and can be output to a discrete output or a power switch.
192 192  
187 +=== Charge map ===
193 193  
194 -1.
195 -11.
196 -111. Charge map
197 -
198 198  The BMS Main 3 device calculates the maximum allowable charge current values in respect to SOC, battery temperature, contactor temperature and cell voltage.
199 199  
200 200  Calculated current values are sent to a charger or an intellectual load over the CAN bus. External devices based on received data provide correct battery operation.
... ... @@ -201,7 +201,7 @@
201 201  
202 202  To configure parameters for determining the charge current limit, select the "Control → Charge map" section:
203 203  
204 -[[image:1733322637793-171.png]]
195 +[[image:1733322637793-171.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="177" width="800"]]
205 205  
206 206  In this section:
207 207  
... ... @@ -221,11 +221,8 @@
221 221  
222 222  Charging current limit = Maximum charging current × Kcs × Kcc × Kcv × Kct
223 223  
215 +=== Discharge map ===
224 224  
225 -1.
226 -11.
227 -111. Discharge map
228 -
229 229  The BMS Main 3 device calculates the maximum allowable discharge current values in respect to SOC, battery temperature, contactor temperature and cell voltage.
230 230  
231 231  Calculated current values are sent to a charger or an intellectual load over the CAN bus.
... ... @@ -232,7 +232,7 @@
232 232  
233 233  To configure parameters for determining the discharge current limit, select the "Control → Discharge map" section:
234 234  
235 -[[image:1733322637795-310.png]]
223 +[[image:1733322637795-310.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="178" width="800"]]
236 236  
237 237  In this section:
238 238  
... ... @@ -252,16 +252,13 @@
252 252  
253 253  Discharging current limit = Maximum discharging current × Kds × Kdc × Kdv × Kdt
254 254  
243 +=== Charge map (PEAK & CONTINUOUS) ===
255 255  
256 -1.
257 -11.
258 -111. Charge map (PEAK & CONTINUOUS)
259 -
260 260  The BMS Main 3 has an alternative algorithm for the maximum allowed charging current based on peak and continuous battery operating modes.
261 261  
262 262  To configure parameters for determining the charge current limit, select the "Control → Charge map (PEAK & CONTINUOUS)" section:
263 263  
264 -[[image:1733322637796-187.png]]
249 +[[image:1733322637796-187.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="145" width="800"]]
265 265  
266 266  In this section:
267 267  
... ... @@ -276,7 +276,7 @@
276 276  
277 277  The maximum charging current value equals to the peak or continuous current according to the following diagram:
278 278  
279 -[[image:1733322717451-608.png]]
264 +[[image:1733322717451-608.png||data-xwiki-image-style-alignment="center"]]
280 280  
281 281  I,,peak,, = Maximum PEAK charge current × K,,cp,,
282 282  
... ... @@ -283,15 +283,13 @@
283 283  I,,continuous,, = Maximum CONTINUOUS charge current × K,,cc,,
284 284  
285 285  
286 -1.
287 -11.
288 -111. Discharge map (PEAK & CONTINUOUS)
271 +=== Discharge map (PEAK & CONTINUOUS) ===
289 289  
290 290  The BMS Main 3 has an alternative algorithm for the maximum allowed discharging current based on peak and continuous battery operating modes.
291 291  
292 292  To configure parameters for determining the discharge current limit, select the "Control → Discharge map (PEAK & CONTINUOUS)" section:
293 293  
294 -[[image:1733322735595-661.png]]
277 +[[image:1733322735595-661.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="145" width="800"]]
295 295  
296 296  In this section:
297 297  
... ... @@ -306,17 +306,14 @@
306 306  
307 307  The maximum discharging current value equals to the peak or continuous current according to following diagram:
308 308  
309 -[[image:1733322753429-968.png]]
292 +[[image:1733322753429-968.png||data-xwiki-image-style-alignment="center"]]
310 310  
311 311  I,,peak,, = Maximum PEAK discharge current × K,,dp,,
312 312  
313 313  I,,continuous,, = Maximum CONTINUOUS discharge current × K,,dc,,
314 314  
298 +=== Charge ===
315 315  
316 -1.
317 -11.
318 -111. Charge
319 -
320 320  There are two contactors that serve charging the battery: a charging contactor and an allow charging contactor. With the help of the allow charging contactor, the BMS commands the charger to start or stop charging.
321 321  
322 322  The device supports three charge control algorithms:
... ... @@ -367,7 +367,7 @@
367 367  
368 368  To change the parameters of the battery charge control algorithm, select the "Control → Charge" section:
369 369  
370 -[[image:1733322798914-813.png]]
350 +[[image:1733322798914-813.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="327" width="800"]]
371 371  
372 372  In this section:
373 373  
... ... @@ -390,9 +390,7 @@
390 390  
391 391  Note – The allow charging contactor closes under two independent conditions: 1) the voltage on the cells reaches the “Voltage to reset the “Ready to charge"” level and 2) the "Delay before recharging" time has passed since the opening of the allow charging contactor.
392 392  
393 -1.
394 -11.
395 -111. Discharge
373 +=== Discharge ===
396 396  
397 397  The device controls the discharging contactor to connect battery to the load.
398 398  
... ... @@ -444,10 +444,8 @@
444 444  
445 445  To change the parameters of the battery discharge control algorithm, select the "Control → Discharge" section:
446 446  
447 -[[image:file:///C:/Users/INASIB~~1/AppData/Local/Temp/msohtmlclip1/01/clip_image001.png||alt="A screenshot of a computer
425 +[[image:1733323750262-841.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="360" width="800"]]
448 448  
449 -Description automatically generated"]]
450 -
451 451  In this section:
452 452  
453 453  * Enable – a flag to activate the discharge control;
... ... @@ -468,26 +468,20 @@
468 468  * Voltage to clear the “Ready to discharge” – a threshold voltage level on the cell, V; if the voltage of any cell is below this level, the “Ready to discharge” signal is cleared;
469 469  * Voltage to reset the “Ready to discharge” – a tolerant voltage level on the cell, V; if all cells voltages are above the tolerant level, the “Ready to discharge” signal is set;
470 470  
447 +=== Charge/Discharge ===
471 471  
472 -1.
473 -11.
474 -111. Charge/Discharge
475 -
476 476  The BMS Main 3 device can control the charging/discharging contactor, which combines algorithms of charging and discharging contactor. It behaves as a charging contactor when “Charge request” or “Charger connected” is set, otherwise – as a discharging contactor.
477 477  
478 478  The charging/discharging contactor control is configured in the “Control – Charge/Discharge” section:
479 479  
480 -[[image:1733322827919-875.png]]
453 +[[image:1733322827919-875.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="85" width="800"]]
481 481  
482 482  In this section:
483 483  
484 484  * Enable – a flag to enable the charge/discharge controller.
485 485  
459 +=== Discharge (AUX) ===
486 486  
487 -1.
488 -11.
489 -111. Discharge (AUX)
490 -
491 491  The BMS Main 3 device can control the power supply of external equipment using the auxiliary (AUX) discharging contactor. An example of external equipment can be an inverter that converts DC to AC to power a service laptop and other devices.
492 492  
493 493  The power supply circuit of the external equipment using the auxiliary (AUX) discharging contactor is independent of the battery load circuit. The closing and opening of the auxiliary (AUX) discharging contactor is performed according to its program.
... ... @@ -500,7 +500,7 @@
500 500  
501 501  To change the parameters of the powering of external equipment, select the "Control → Discharge (AUX)" section:
502 502  
503 -[[image:1733322827920-878.png]]
473 +[[image:1733322827920-878.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="130" width="800"]]
504 504  
505 505  In this section:
506 506  
... ... @@ -513,9 +513,7 @@
513 513  * Maximum voltage – maximum battery voltage, V;
514 514  * Switch off the discharging (AUX) contactor on errors – the auxiliary (AUX) discharging contactor opens if the following errors occur: Undervoltage, Overcurrent, High temperature (DCH), Short circuit, Critical error.
515 515  
516 -1.
517 -11.
518 -111. Main contactor
486 +=== Main contactor ===
519 519  
520 520  The BMS Main 3 device controls the main contactor. The main contactor is usually placed in the common (minus) battery line for opening the charge and discharge circuits in case of sealing of the charging or discharging contactors.
521 521  
... ... @@ -557,7 +557,7 @@
557 557  
558 558  To change the parameters of the main contactor, select the "Control → Main contactor" section:
559 559  
560 -[[image:1733322872744-536.png]]
528 +[[image:1733322872744-536.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="105" width="800"]]
561 561  
562 562  In this section:
563 563  
... ... @@ -570,9 +570,7 @@
570 570  * Delay before opening the contactor – a time which is used to detect conditions for opening the contactor, s;
571 571  * Keep the contactor open until the device is restarted – a flag for keeping the main contactor open until the system is reset.
572 572  
573 -1.
574 -11.
575 -111. Cell balancing
541 +=== Cell balancing ===
576 576  
577 577  Balancing makes the voltage of all cells equal to the minimum cell voltage.
578 578  
... ... @@ -598,7 +598,7 @@
598 598  
599 599  To change the cell balancing parameters, select the "Control → Cell balancing" section:
600 600  
601 -[[image:1733322883460-118.png]]
567 +[[image:1733322883460-118.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="114" width="800"]]
602 602  
603 603  In this section:
604 604  
... ... @@ -608,7 +608,7 @@
608 608  ** Balance on charge or relaxed - balancing is performed while and after the charging and in the relaxed state (in “Charge ON”, “Charge OFF”, “Relaxed (after charging)” and “Relaxed (after discharging)” states);
609 609  ** Balance always – balancing is always performed regardless the battery state;
610 610  
611 -[[image:1733322883462-975.png]]
577 +[[image:1733322883462-975.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="74" width="600"]]
612 612  
613 613  * Minimum cell voltage to start balancing, V;
614 614  * Voltage deviation to start balancing;
... ... @@ -615,11 +615,8 @@
615 615  * Voltage deviation to stop balancing;
616 616  * Command to discharge all cells – a flag to force the balancing of all cells.
617 617  
584 +=== Series balancing ===
618 618  
619 -1.
620 -11.
621 -111. Series balancing
622 -
623 623  The BMS Main 3 device supports work with two independent (galvanically unrelated) cell series. To monitor the status of two series, two current sensors are used. A series of cells must be equivalent: they must have the same number of cells and the same capacity.
624 624  
625 625  Since the series of cells can operate at different loads, they must be balanced. For this, the BMS Main 3 provides two signals to power switches: “Balancing series 1” and “Balancing series 2”, as well as a combined algorithm that considers both the voltage of each series and the charge that these series gave load. The “Balancing series 1” and “Balancing series 2” signals are used to connect high-power balancing resistors in parallel with cell series 1 and 2.
... ... @@ -633,7 +633,7 @@
633 633  
634 634  To change the series balancing parameters, select the "Control → Series balancing" section:
635 635  
636 -[[image:1733322892811-410.png]]
599 +[[image:1733322892811-410.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="126" width="800"]]
637 637  
638 638  In this section:
639 639  
... ... @@ -643,13 +643,10 @@
643 643  * Balancing threshold, V;
644 644  * Coulomb threshold – the difference of the charges Qthr, given by a series of cells, above which balancing to be started, Ah;
645 645  * Period – a period to reset of charge counters for each series (to avoid accumulation of error), second;
646 -* Do not sum series voltages – a flag to disable the summing of series voltages.
609 +* Do not sum series voltages – a flag to disable the summing of series voltages.3
647 647  
611 +=== Power down ===
648 648  
649 -1.
650 -11.
651 -111. Power down
652 -
653 653  The BMS Main 3 device can shut down itself if the battery voltage is low or the battery is idle for a long time.
654 654  
655 655  Shutting down the battery system is performed according to the following conditions:
... ... @@ -661,7 +661,7 @@
661 661  
662 662  To change the parameters of the power down control, select the "Control → Power down" section:
663 663  
664 -[[image:1733322892813-562.png]]
624 +[[image:1733322892813-562.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="103" width="800"]]
665 665  
666 666  In this section:
667 667  
... ... @@ -671,13 +671,11 @@
671 671  * Power down if KEYRUN and CHARGE_ON are cleared – a flag to power down the device if KEYRUN and CHARGE_ON signals are cleared;
672 672  * Delay before setting the internal power down signal – a delay before turning off the device power when removing KEYRUN and CHARGE_ON or receiving the “Power down request” command, ms.
673 673  
674 -1.
675 -11.
676 -111. Heater
634 +=== Heater ===
677 677  
678 678  To change the parameters of the heater control algorithm, select the "Control → Heater" section:
679 679  
680 -[[image:1733322901923-144.png]]
638 +[[image:1733322901923-144.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="108" width="800"]]
681 681  
682 682  In this section:
683 683  
... ... @@ -700,14 +700,11 @@
700 700  
701 701  If there is the "Heater" signal, the heater contactor closes and/or a signal is output to the corresponding digital output.
702 702  
661 +=== Cooler ===
703 703  
704 -1.
705 -11.
706 -111. Cooler
707 -
708 708  To change the parameters of the cooler control algorithm, select the "Control → Cooler" section:
709 709  
710 -[[image:1733322901924-962.png]]
665 +[[image:1733322901924-962.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="107" width="800"]]
711 711  
712 712  In this section:
713 713  
... ... @@ -730,16 +730,13 @@
730 730  
731 731  If there is the "Cooler" signal, the cooler contactor closes and/or a signal is output to the corresponding digital output.
732 732  
688 +=== High voltage ===
733 733  
734 -1.
735 -11.
736 -111. High voltage
737 -
738 738  The BMS Main 3 device has an ability to measure high voltages before and after contactors.
739 739  
740 740  To change the parameters of high voltage fault, select the "Control → High voltage" section:
741 741  
742 -[[image:1733322914683-203.png]]
694 +[[image:1733322914683-203.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="87" width="800"]]
743 743  
744 744  In this section:
745 745  
... ... @@ -751,11 +751,8 @@
751 751  
752 752  **If there is the “High voltage fault”, the “Critical error” is generated and all contactors open.**
753 753  
706 +=== Cell analysis ===
754 754  
755 -1.
756 -11.
757 -111. Cell analysis
758 -
759 759  The battery discharge characteristic – the dependence Uocv = Uocv(DOD) – is used to determine the tabular dependence Uocv = Uocv(SOC, t°C), which is necessary for calculating the battery charge level.
760 760  
761 761  The BMS Main 3 device can automatically determine the battery discharge characteristic.
... ... @@ -767,7 +767,7 @@
767 767  
768 768  To configure parameters for determining the discharge characteristic of the battery, select the "Control → Cell analysis" section:
769 769  
770 -[[image:1733322914685-558.png]]
719 +[[image:1733322914685-558.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="107" width="800"]]
771 771  
772 772  In this section:
773 773  
1733323750262-841.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +69.6 KB
Content
1735054851946-552.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +22.9 KB
Content
1735056052237-170.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +32.1 KB
Content
1735056107942-306.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +33.0 KB
Content