Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/06/18 15:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -12,7 +12,7 @@ 12 12 13 13 Assignments of discrete inputs are configured in the "Signals → Input discrete signals → Assignments" section: 14 14 15 -[[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height=" 236" width="800"]]15 +[[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="177" width="600"]] 16 16 17 17 The device supports the following assignments for discrete inputs: 18 18 ... ... @@ -36,11 +36,11 @@ 36 36 * Circuit breaker status – status of protection disconnector; 37 37 * Balancing request – a request to balance the cells; 38 38 * Close Main contactor – a request to close the main contactor; 39 -* Close External 1 – a request to close the External1 discreteoutput (ifassigned).39 +* Close External 1 – a request to close the first external contactor. 40 40 41 41 Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section: 42 42 43 -[[image:173 5054242278-319.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="800"]]43 +[[image:1733320685770-300.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="209" width="800"]] 44 44 45 45 The behavior of “KEYRUN” signal can be configured in the "Signals → Input discrete signals → KEYRUN mode" section: 46 46 ... ... @@ -62,7 +62,7 @@ 62 62 63 63 Current sensor settings are configured in the "Signals → Current sensor" section: 64 64 65 -[[image:173 5054422436-925.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="391" width="800"]]65 +[[image:1733320685773-566.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="361" width="800"]] 66 66 67 67 The device supports the following current sensor settings: 68 68 ... ... @@ -125,7 +125,7 @@ 125 125 126 126 Assignments of discrete outputs are configured in the "Signals → Output discrete signals → Assignments" section: 127 127 128 -[[image:173 5054536275-447.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]]128 +[[image:1733320685778-896.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]] 129 129 130 130 The device supports the following assignments for discrete outputs: 131 131 ... ... @@ -148,9 +148,8 @@ 148 148 * Balancing 2 – balancing the second series of cells; 149 149 * Ready to charge – the battery is ready to be charged; 150 150 * Ready to discharge – the battery is ready to be discharged; 151 -* Power up – an indication of BMS power status; 152 -* General error – state of the configurable (general) error; 153 -* External 1 – a signal 151 +* Power up – an indication of BMS power status. 152 +* General error – state of the configurable (general) error. 154 154 155 155 Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section: 156 156
- 1735054422436-925.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -83.9 KB - Content
- 1735054536275-447.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -28.7 KB - Content