... ... @@ -14,30 +14,8 @@
14 14  
15 15  [[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]]
16 16  
17 -The device supports the following assignments for discrete inputs:
17 +A list of available discrete input assignments is available in
18 18  
19 -* No input – input is not used;
20 -* Battery cover – a signal from the battery cover;
21 -* Charger connected – a signal indicating that charger is connected;
22 -* Power up/down request – a request to power down the device;
23 -* Inhibit charging – a command to open the charging contactor;
24 -* Inhibit discharging – a command to open the discharging contactor;
25 -* CH contactor feedback – a signal from charging contactor feedback loop;
26 -* DCH contactor feedback – a signal from discharging contactor feedback loop;
27 -* Insulation status – a signal from an insulation monitoring device;
28 -* Charge request – a request to close the charging contactor;
29 -* Precharge request – a request to close the precharging contactor;
30 -* Discharge request – a request to close the discharging contactor;
31 -* PCH contactor feedback – a signal from precharging contactor feedback loop;
32 -* CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop;
33 -* Main contactor feedback – a signal from main contactor feedback loop;
34 -* Interlock – a signal from interlock loop;
35 -* Fuse 1, Fuse 2, Fuse 3 – signals from fuses;
36 -* Circuit breaker status – status of protection disconnector;
37 -* Balancing request – a request to balance the cells;
38 -* Close Main contactor – a request to close the main contactor;
39 -* Close External 1 – a request to close the External 1 discrete output (if assigned).
40 -
41 41  Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section:
42 42  
43 43  [[image:1735054242278-319.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="800"]]
... ... @@ -125,7 +125,7 @@
125 125  
126 126  Assignments of discrete outputs are configured in the "Signals → Output discrete signals → Assignments" section:
127 127  
128 -[[image:1733320685778-896.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]]
106 +[[image:1735054536275-447.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]]
129 129  
130 130  The device supports the following assignments for discrete outputs:
131 131  
... ... @@ -148,12 +148,13 @@
148 148  * Balancing 2 – balancing the second series of cells;
149 149  * Ready to charge – the battery is ready to be charged;
150 150  * Ready to discharge – the battery is ready to be discharged;
151 -* Power up – an indication of BMS power status.
152 -* General error – state of the configurable (general) error.
129 +* Power up – an indication of BMS power status;
130 +* General error – state of the configurable (general) error;
131 +* External 1 – a signal that activates by the remote request.
153 153  
154 154  Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section:
155 155  
156 -[[image:1733320685780-193.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]]
135 +[[image:1735054654975-772.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]]
157 157  
158 158  === Power switches ===
159 159  
... ... @@ -161,12 +161,12 @@
161 161  
162 162  Assignments of power switches are configured in the "Signals → Power switches → Assignments" section:
163 163  
164 -[[image:1733320685782-487.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="168" width="800"]]
143 +[[image:1735054694689-808.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="167" width="800"]]
165 165  
166 -The device supports the same switch assignments as discrete outputs.
145 +The device supports the same switch assignments as discrete outputs (see [[Output discrete signals>>doc:||anchor="HOutputdiscretesignals"]]).
167 167  
168 168  Inversion flags for switches are configured in the “Signals → Power switches → Inversion” section:
169 169  
170 -[[image:1733320685783-267.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="150" width="800"]]
149 +[[image:1735054793459-953.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="149" width="800"]]
171 171  
172 172  
1735054654975-772.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +20.3 KB
Content
1735054694689-808.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +33.5 KB
Content
1735054793459-953.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +23.3 KB
Content