Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/06/18 15:33
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS Main1 +drafts.bms-main-3.3\. Configuration.WebHome - Content
-
... ... @@ -1,11 +1,5 @@ 1 -(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Configuration = 1 +== 3.2.1 Discrete inputs == 3 3 4 -(% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 -== Inputs and outputs == 6 - 7 -=== Discrete inputs === 8 - 9 9 The BMS Main 3 device has 6 discrete inputs that detect signal line closing to the virtual ground, and 2 inputs that detect 9-32V input voltage. For each discrete input, its assignment and inversion flag are set. 10 10 11 11 Also, BMS has two additional configurable inputs named “KEYRUN” and “CHARGE_ON”, each serves 9-32V input voltage. Those inputs serve as power buttons with additional functions that can be set. ... ... @@ -12,7 +12,7 @@ 12 12 13 13 Assignments of discrete inputs are configured in the "Signals → Input discrete signals → Assignments" section: 14 14 15 -[[image:173 5053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="177" width="600"]]9 +[[image:1733320685766-185.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="226" width="800"]] 16 16 17 17 The device supports the following assignments for discrete inputs: 18 18 ... ... @@ -35,8 +35,7 @@ 35 35 * Fuse 1, Fuse 2, Fuse 3 – signals from fuses; 36 36 * Circuit breaker status – status of protection disconnector; 37 37 * Balancing request – a request to balance the cells; 38 -* Close Main contactor – a request to close the main contactor; 39 -* Close External 1 – a request to close the first external contactor. 32 +* Close Main contactor – a request to close the main contactor. 40 40 41 41 Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section: 42 42 ... ... @@ -56,7 +56,7 @@ 56 56 * Set “Discharge request” – power on device and set “Discharge request” signal immediately; 57 57 * Set “Charge request” – power on device and set “Charge request” signal immediately. 58 58 59 -== =Current sensor ===52 +== 3.2.2 Current sensor == 60 60 61 61 The BMS Main 3 device has an ability to measure battery current by 3 external Hall-Effect current sensors. 62 62 ... ... @@ -87,7 +87,7 @@ 87 87 * Calibration time – calibration time of the current sensor, millisecond; 88 88 * Recalibrate current sensor – a command to calibrate the current sensor manually. 89 89 90 -== =Shunt sensor (CAN bus) ===83 +== 3.2.3 Shunt sensor (CAN bus) == 91 91 92 92 The BMS Main 3 device has an ability to measure battery current via a shunt sensor, connected to the CAN bus. 93 93 ... ... @@ -109,7 +109,7 @@ 109 109 * Mean value threshold – T,,M,, level, A (if module of instantaneous current (I,,I,,) which is received from the shunt sensor is between T,,M,, and T,,0,,, the BMS will use mean value of current I,,M,,; if I,,I,, is greater than T,,M,,, the BMS will use instantaneous value of current I,,I,,); 110 110 * Zero threshold – T,,0,, level, A (if module of instantaneous current (I,,I,,) which is received from the shunt sensor is lower than T,,0,,, the BMS will assume that current flowing through the battery is zero); 111 111 112 -=== Temperature sensors === 105 +=== 3.2.4 Temperature sensors === 113 113 114 114 Temperature sensors settings are configured in the "Signals → Temperature sensors" section: 115 115 ... ... @@ -119,7 +119,7 @@ 119 119 120 120 * Type – a type of temperature sensors. 121 121 122 -=== Output discrete signals === 115 +=== 3.2.5 Output discrete signals === 123 123 124 124 The BMS Main 3 device has 4 open drain type outputs. For each discrete output, its assignment and inversion flag are set. 125 125 ... ... @@ -155,7 +155,7 @@ 155 155 156 156 [[image:1733320685780-193.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]] 157 157 158 -=== Power switches === 151 +=== 3.2.6 Power switches === 159 159 160 160 The BMS Main 3 device has 6 power switches to drive contactors. For each switch, its assignment and inversion flag are set. 161 161
- 1735053944168-184.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -40.5 KB - Content