Changes for page 3.2 Inputs and outputs

Last modified by Admin on 2025/06/18 15:33

From version 5.1
edited by Admin
on 2024/12/24 15:25
Change comment: Uploaded new attachment "1735053944168-184.png", version {1}
To version 8.2
edited by Admin
on 2024/12/24 15:36
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -12,7 +12,7 @@
12 12  
13 13  Assignments of discrete inputs are configured in the "Signals → Input discrete signals → Assignments" section:
14 14  
15 -[[image:1733320685766-185.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="226" width="800"]]
15 +[[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]]
16 16  
17 17  The device supports the following assignments for discrete inputs:
18 18  
... ... @@ -35,11 +35,12 @@
35 35  * Fuse 1, Fuse 2, Fuse 3 – signals from fuses;
36 36  * Circuit breaker status – status of protection disconnector;
37 37  * Balancing request – a request to balance the cells;
38 -* Close Main contactor – a request to close the main contactor.
38 +* Close Main contactor – a request to close the main contactor;
39 +* Close External 1 – a request to close the External 1 discrete output (if assigned).
39 39  
40 40  Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section:
41 41  
42 -[[image:1733320685770-300.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="209" width="800"]]
43 +[[image:1735054242278-319.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="800"]]
43 43  
44 44  The behavior of “KEYRUN” signal can be configured in the "Signals → Input discrete signals → KEYRUN mode" section:
45 45  
... ... @@ -61,7 +61,7 @@
61 61  
62 62  Current sensor settings are configured in the "Signals → Current sensor" section:
63 63  
64 -[[image:1733320685773-566.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="361" width="800"]]
65 +[[image:1735054422436-925.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="391" width="800"]]
65 65  
66 66  The device supports the following current sensor settings:
67 67  
... ... @@ -124,7 +124,7 @@
124 124  
125 125  Assignments of discrete outputs are configured in the "Signals → Output discrete signals → Assignments" section:
126 126  
127 -[[image:1733320685778-896.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]]
128 +[[image:1735054536275-447.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]]
128 128  
129 129  The device supports the following assignments for discrete outputs:
130 130  
... ... @@ -147,8 +147,9 @@
147 147  * Balancing 2 – balancing the second series of cells;
148 148  * Ready to charge – the battery is ready to be charged;
149 149  * Ready to discharge – the battery is ready to be discharged;
150 -* Power up – an indication of BMS power status.
151 -* General error – state of the configurable (general) error.
151 +* Power up – an indication of BMS power status;
152 +* General error – state of the configurable (general) error;
153 +* External 1 – a signal
152 152  
153 153  Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section:
154 154  
1735054242278-319.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +29.5 KB
Content
1735054422436-925.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +83.9 KB
Content
1735054536275-447.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +28.7 KB
Content