Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/06/18 15:33
Summary
-
Page properties (2 modified, 0 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - Battery managementystems.BMS Main1 +drafts.bms-main-3.3\. Settings.WebHome - Content
-
... ... @@ -1,11 +1,5 @@ 1 -(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Settings = 1 +== 3.2.1 Discrete inputs == 3 3 4 -(% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 -== Inputs and outputs == 6 - 7 -=== Discrete inputs === 8 - 9 9 The BMS Main 3 device has 6 discrete inputs that detect signal line closing to the virtual ground, and 2 inputs that detect 9-32V input voltage. For each discrete input, its assignment and inversion flag are set. 10 10 11 11 Also, BMS has two additional configurable inputs named “KEYRUN” and “CHARGE_ON”, each serves 9-32V input voltage. Those inputs serve as power buttons with additional functions that can be set. ... ... @@ -55,7 +55,7 @@ 55 55 * Set “Discharge request” – power on device and set “Discharge request” signal immediately; 56 56 * Set “Charge request” – power on device and set “Charge request” signal immediately. 57 57 58 -== =Current sensor ===52 +== 3.2.2 Current sensor == 59 59 60 60 The BMS Main 3 device has an ability to measure battery current by 3 external Hall-Effect current sensors. 61 61 ... ... @@ -86,7 +86,7 @@ 86 86 * Calibration time – calibration time of the current sensor, millisecond; 87 87 * Recalibrate current sensor – a command to calibrate the current sensor manually. 88 88 89 -== =Shunt sensor (CAN bus) ===83 +== 3.2.3 Shunt sensor (CAN bus) == 90 90 91 91 The BMS Main 3 device has an ability to measure battery current via a shunt sensor, connected to the CAN bus. 92 92 ... ... @@ -108,7 +108,7 @@ 108 108 * Mean value threshold – T,,M,, level, A (if module of instantaneous current (I,,I,,) which is received from the shunt sensor is between T,,M,, and T,,0,,, the BMS will use mean value of current I,,M,,; if I,,I,, is greater than T,,M,,, the BMS will use instantaneous value of current I,,I,,); 109 109 * Zero threshold – T,,0,, level, A (if module of instantaneous current (I,,I,,) which is received from the shunt sensor is lower than T,,0,,, the BMS will assume that current flowing through the battery is zero); 110 110 111 -=== Temperature sensors === 105 +=== 3.2.4 Temperature sensors === 112 112 113 113 Temperature sensors settings are configured in the "Signals → Temperature sensors" section: 114 114 ... ... @@ -118,7 +118,7 @@ 118 118 119 119 * Type – a type of temperature sensors. 120 120 121 -=== Output discrete signals === 115 +=== 3.2.5 Output discrete signals === 122 122 123 123 The BMS Main 3 device has 4 open drain type outputs. For each discrete output, its assignment and inversion flag are set. 124 124 ... ... @@ -154,7 +154,7 @@ 154 154 155 155 [[image:1733320685780-193.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]] 156 156 157 -=== Power switches === 151 +=== 3.2.6 Power switches === 158 158 159 159 The BMS Main 3 device has 6 power switches to drive contactors. For each switch, its assignment and inversion flag are set. 160 160