Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/06/18 15:33
Summary
-
Page properties (2 modified, 0 added, 0 removed)
-
Attachments (0 modified, 9 added, 0 removed)
Details
- Page properties
-
- Parent
-
... ... @@ -1,1 +1,1 @@ 1 - drafts.BMS Main 3.3\.Settings.WebHome1 +Battery management systems.BMS Main 3.3\. Configuration.WebHome - Content
-
... ... @@ -1,5 +1,5 @@ 1 1 (% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 -= Settings=2 += Configuration = 3 3 4 4 (% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 5 == Inputs and outputs == ... ... @@ -12,34 +12,16 @@ 12 12 13 13 Assignments of discrete inputs are configured in the "Signals → Input discrete signals → Assignments" section: 14 14 15 -[[image:173 3320685766-185.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="226" width="800"]]15 +[[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]] 16 16 17 -The device supports the following assignments for discrete inputs: 17 +(% class="box infomessage" %) 18 +((( 19 +A list of available **discrete input** assignments is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]. 20 +))) 18 18 19 -* No input – input is not used; 20 -* Battery cover – a signal from the battery cover; 21 -* Charger connected – a signal indicating that charger is connected; 22 -* Power up/down request – a request to power down the device; 23 -* Inhibit charging – a command to open the charging contactor; 24 -* Inhibit discharging – a command to open the discharging contactor; 25 -* CH contactor feedback – a signal from charging contactor feedback loop; 26 -* DCH contactor feedback – a signal from discharging contactor feedback loop; 27 -* Insulation status – a signal from an insulation monitoring device; 28 -* Charge request – a request to close the charging contactor; 29 -* Precharge request – a request to close the precharging contactor; 30 -* Discharge request – a request to close the discharging contactor; 31 -* PCH contactor feedback – a signal from precharging contactor feedback loop; 32 -* CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop; 33 -* Main contactor feedback – a signal from main contactor feedback loop; 34 -* Interlock – a signal from interlock loop; 35 -* Fuse 1, Fuse 2, Fuse 3 – signals from fuses; 36 -* Circuit breaker status – status of protection disconnector; 37 -* Balancing request – a request to balance the cells; 38 -* Close Main contactor – a request to close the main contactor. 39 - 40 40 Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section: 41 41 42 -[[image:173 3320685770-300.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="209" width="800"]]24 +[[image:1735054242278-319.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="800"]] 43 43 44 44 The behavior of “KEYRUN” signal can be configured in the "Signals → Input discrete signals → KEYRUN mode" section: 45 45 ... ... @@ -61,7 +61,7 @@ 61 61 62 62 Current sensor settings are configured in the "Signals → Current sensor" section: 63 63 64 -[[image:173 3320685773-566.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="361" width="800"]]46 +[[image:1735054422436-925.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="391" width="800"]] 65 65 66 66 The device supports the following current sensor settings: 67 67 ... ... @@ -112,11 +112,13 @@ 112 112 113 113 Temperature sensors settings are configured in the "Signals → Temperature sensors" section: 114 114 115 -[[image:17 33320685777-354.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="97" width="800"]]97 +[[image:1750260739668-708.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="85" width="800"]] 116 116 117 117 In this section: 118 118 119 -* Type – a type of temperature sensors. 101 +* Type of cell temperature sensors – a type of temperature sensors connected to BMS Logic devices and used to measure cells temperature; 102 +* Unused cell temperature sensors – a bitfield to select unused temperature sensors on each BMS Logic; 103 +* Type of temperature sensors 1 and 2 – a type of temperature sensors connected to BMS Main 3. 120 120 121 121 === Output discrete signals === 122 122 ... ... @@ -124,35 +124,16 @@ 124 124 125 125 Assignments of discrete outputs are configured in the "Signals → Output discrete signals → Assignments" section: 126 126 127 -[[image:173 3320685778-896.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]]111 +[[image:1735054536275-447.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]] 128 128 129 -The device supports the following assignments for discrete outputs: 113 +(% class="box infomessage" %) 114 +((( 115 +A list of available **discrete output** assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 116 +))) 130 130 131 -* No output – output is not used. 132 -* Low SOC – a signal corresponding the low SOC of the battery; 133 -* High charging current – charging current is high; 134 -* Main contactor – state of the main contactor; 135 -* Charging – state of the charging contactor; 136 -* Allow charging – a signal for a charger to start charging; 137 -* Charging current present – the presence of the charging current; 138 -* Precharging – state of the precharging contactor; 139 -* Discharging – state of the discharging contactor; 140 -* Discharging current present – the presence of the discharging current; 141 -* Discharging (AUX) – state of the auxiliary discharging contactor; 142 -* Power down ACK – an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request; 143 -* Charging/discharging - state of the charging/discharging contactor; 144 -* Heater – a command to turn on a heater; 145 -* Cooler – a command to turn on a cooler; 146 -* Balancing 1 – balancing the first series of cells; 147 -* Balancing 2 – balancing the second series of cells; 148 -* Ready to charge – the battery is ready to be charged; 149 -* Ready to discharge – the battery is ready to be discharged; 150 -* Power up – an indication of BMS power status. 151 -* General error – state of the configurable (general) error. 152 - 153 153 Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section: 154 154 155 -[[image:173 3320685780-193.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]]120 +[[image:1735054654975-772.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]] 156 156 157 157 === Power switches === 158 158 ... ... @@ -160,12 +160,15 @@ 160 160 161 161 Assignments of power switches are configured in the "Signals → Power switches → Assignments" section: 162 162 163 -[[image:173 3320685782-487.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="168" width="800"]]128 +[[image:1735054694689-808.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="167" width="800"]] 164 164 165 -The device supports the same switch assignments as discrete outputs. 130 +(% class="box infomessage" %) 131 +((( 132 +A list of available **switch **assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 133 +))) 166 166 167 167 Inversion flags for switches are configured in the “Signals → Power switches → Inversion” section: 168 168 169 -[[image:173 3320685783-267.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="150" width="800"]]137 +[[image:1735054793459-953.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="149" width="800"]] 170 170 171 171
- 1735053944168-184.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +40.5 KB - Content
- 1735054242278-319.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +29.5 KB - Content
- 1735054422436-925.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +83.9 KB - Content
- 1735054536275-447.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +28.7 KB - Content
- 1735054654975-772.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +20.3 KB - Content
- 1735054694689-808.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +33.5 KB - Content
- 1735054793459-953.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.3 KB - Content
- 1750259757728-314.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.5 KB - Content
- 1750260739668-708.png
-
- Author
-
... ... @@ -1,0 +1,1 @@ 1 +XWiki.admin - Size
-
... ... @@ -1,0 +1,1 @@ 1 +23.5 KB - Content