Changes for page 3.2 Inputs and outputs

Last modified by Admin on 2025/06/18 15:33

From version 3.1
edited by Admin
on 2024/12/04 15:54
Change comment: There is no comment for this version
To version 6.1
edited by Admin
on 2024/12/24 15:30
Change comment: Uploaded new attachment "1735054242278-319.png", version {1}

Summary

Details

Page properties
Parent
... ... @@ -1,1 +1,1 @@
1 -drafts.bms-main-3.3\. Settings.WebHome
1 +Battery management systems.BMS Main 3.3\. Configuration.WebHome
Content
... ... @@ -1,8 +1,8 @@
1 -(% data-numbered-headings-start="2" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 -= =
1 +(% data-numbered-headings-start="3" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
2 += Configuration =
3 3  
4 -(% data-numbered-headings-start="1" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 -== ==
4 +(% data-numbered-headings-start="2" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %)
5 +== Inputs and outputs ==
6 6  
7 7  === ​​​​​​Discrete inputs ===
8 8  
... ... @@ -12,7 +12,7 @@
12 12  
13 13  Assignments of discrete inputs are configured in the "Signals → Input discrete signals → Assignments" section:
14 14  
15 -[[image:1733320685766-185.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="226" width="800"]]
15 +[[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="177" width="600"]]
16 16  
17 17  The device supports the following assignments for discrete inputs:
18 18  
... ... @@ -35,7 +35,8 @@
35 35  * Fuse 1, Fuse 2, Fuse 3 – signals from fuses;
36 36  * Circuit breaker status – status of protection disconnector;
37 37  * Balancing request – a request to balance the cells;
38 -* Close Main contactor – a request to close the main contactor.
38 +* Close Main contactor – a request to close the main contactor;
39 +* Close External 1 – a request to close the first external contactor.
39 39  
40 40  Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section:
41 41  
1735053944168-184.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +40.5 KB
Content
1735054242278-319.png
Author
... ... @@ -1,0 +1,1 @@
1 +XWiki.admin
Size
... ... @@ -1,0 +1,1 @@
1 +29.5 KB
Content