Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/06/18 15:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -1,5 +1,11 @@ 1 -== 3.2.1 Discrete inputs == 1 +(% data-numbered-headings-start="2" style="--numbered-headings-start: 2;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 2 += = 2 2 4 +(% data-numbered-headings-start="1" style="--numbered-headings-start: 1;font-size: 0px;color: rgba(0, 0, 0, 0.0);margin-bottom: 0px; margin-top: 0px;" %) 5 +== == 6 + 7 +=== Discrete inputs === 8 + 3 3 The BMS Main 3 device has 6 discrete inputs that detect signal line closing to the virtual ground, and 2 inputs that detect 9-32V input voltage. For each discrete input, its assignment and inversion flag are set. 4 4 5 5 Also, BMS has two additional configurable inputs named “KEYRUN” and “CHARGE_ON”, each serves 9-32V input voltage. Those inputs serve as power buttons with additional functions that can be set. ... ... @@ -49,7 +49,7 @@ 49 49 * Set “Discharge request” – power on device and set “Discharge request” signal immediately; 50 50 * Set “Charge request” – power on device and set “Charge request” signal immediately. 51 51 52 -== 3.2.2Current sensor ==58 +=== Current sensor === 53 53 54 54 The BMS Main 3 device has an ability to measure battery current by 3 external Hall-Effect current sensors. 55 55 ... ... @@ -80,7 +80,7 @@ 80 80 * Calibration time – calibration time of the current sensor, millisecond; 81 81 * Recalibrate current sensor – a command to calibrate the current sensor manually. 82 82 83 -== 3.2.3Shunt sensor (CAN bus) ==89 +=== Shunt sensor (CAN bus) === 84 84 85 85 The BMS Main 3 device has an ability to measure battery current via a shunt sensor, connected to the CAN bus. 86 86 ... ... @@ -102,7 +102,7 @@ 102 102 * Mean value threshold – T,,M,, level, A (if module of instantaneous current (I,,I,,) which is received from the shunt sensor is between T,,M,, and T,,0,,, the BMS will use mean value of current I,,M,,; if I,,I,, is greater than T,,M,,, the BMS will use instantaneous value of current I,,I,,); 103 103 * Zero threshold – T,,0,, level, A (if module of instantaneous current (I,,I,,) which is received from the shunt sensor is lower than T,,0,,, the BMS will assume that current flowing through the battery is zero); 104 104 105 -=== 3.2.4Temperature sensors ===111 +=== Temperature sensors === 106 106 107 107 Temperature sensors settings are configured in the "Signals → Temperature sensors" section: 108 108 ... ... @@ -112,7 +112,7 @@ 112 112 113 113 * Type – a type of temperature sensors. 114 114 115 -=== 3.2.5Output discrete signals ===121 +=== Output discrete signals === 116 116 117 117 The BMS Main 3 device has 4 open drain type outputs. For each discrete output, its assignment and inversion flag are set. 118 118 ... ... @@ -148,7 +148,7 @@ 148 148 149 149 [[image:1733320685780-193.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]] 150 150 151 -=== 3.2.6Power switches ===157 +=== Power switches === 152 152 153 153 The BMS Main 3 device has 6 power switches to drive contactors. For each switch, its assignment and inversion flag are set. 154 154