Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/06/18 15:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 2 removed)
Details
- Page properties
-
- Content
-
... ... @@ -14,10 +14,7 @@ 14 14 15 15 [[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]] 16 16 17 -(% class="box infomessage" %) 18 -((( 19 -A list of available **discrete input** assignments is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]. 20 -))) 17 +A list of available discrete input assignments is available in 21 21 22 22 Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section: 23 23 ... ... @@ -94,13 +94,11 @@ 94 94 95 95 Temperature sensors settings are configured in the "Signals → Temperature sensors" section: 96 96 97 -[[image:17 50260739668-708.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="85" width="800"]]94 +[[image:1733320685777-354.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="97" width="800"]] 98 98 99 99 In this section: 100 100 101 -* Type of cell temperature sensors – a type of temperature sensors connected to BMS Logic devices and used to measure cells temperature; 102 -* Unused cell temperature sensors – a bitfield to select unused temperature sensors on each BMS Logic; 103 -* Type of temperature sensors 1 and 2 – a type of temperature sensors connected to BMS Main 3. 98 +* Type – a type of temperature sensors. 104 104 105 105 === Output discrete signals === 106 106 ... ... @@ -110,11 +110,31 @@ 110 110 111 111 [[image:1735054536275-447.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]] 112 112 113 -(% class="box infomessage" %) 114 -((( 115 -A list of available **discrete output** assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 116 -))) 108 +The device supports the following assignments for discrete outputs: 117 117 110 +* No output – output is not used. 111 +* Low SOC – a signal corresponding the low SOC of the battery; 112 +* High charging current – charging current is high; 113 +* Main contactor – state of the main contactor; 114 +* Charging – state of the charging contactor; 115 +* Allow charging – a signal for a charger to start charging; 116 +* Charging current present – the presence of the charging current; 117 +* Precharging – state of the precharging contactor; 118 +* Discharging – state of the discharging contactor; 119 +* Discharging current present – the presence of the discharging current; 120 +* Discharging (AUX) – state of the auxiliary discharging contactor; 121 +* Power down ACK – an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request; 122 +* Charging/discharging - state of the charging/discharging contactor; 123 +* Heater – a command to turn on a heater; 124 +* Cooler – a command to turn on a cooler; 125 +* Balancing 1 – balancing the first series of cells; 126 +* Balancing 2 – balancing the second series of cells; 127 +* Ready to charge – the battery is ready to be charged; 128 +* Ready to discharge – the battery is ready to be discharged; 129 +* Power up – an indication of BMS power status; 130 +* General error – state of the configurable (general) error; 131 +* External 1 – a signal that activates by the remote request. 132 + 118 118 Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section: 119 119 120 120 [[image:1735054654975-772.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]] ... ... @@ -127,10 +127,7 @@ 127 127 128 128 [[image:1735054694689-808.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="167" width="800"]] 129 129 130 -(% class="box infomessage" %) 131 -((( 132 -A list of available **switch **assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 133 -))) 145 +The device supports the same switch assignments as discrete outputs (see [[Output discrete signals>>doc:||anchor="HOutputdiscretesignals"]]). 134 134 135 135 Inversion flags for switches are configured in the “Signals → Power switches → Inversion” section: 136 136
- 1750259757728-314.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -23.5 KB - Content
- 1750260739668-708.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -23.5 KB - Content