Summary

Details

Page properties
Content
... ... @@ -14,10 +14,7 @@
14 14  
15 15  [[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]]
16 16  
17 -(% class="box infomessage" %)
18 -(((
19 -A list of available **discrete input** assignments is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]].
20 -)))
17 +A list of available discrete input assignments is available in
21 21  
22 22  Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section:
23 23  
... ... @@ -98,10 +98,6 @@
98 98  
99 99  In this section:
100 100  
101 -* Type of cell temperature sensors – a type of temperature sensors connected to BMS Logic devices and used to measure cells temperature;
102 -* Unused cell temperature sensors – a bitfield to select unused temperature sensors on each BMS Logic;ры на каждом BMS Logic;
103 -* Type of temperature sensors 1 and 2 – тип температурных датчиков, подключенных к BMS Main 3.
104 -*
105 105  * Type – a type of temperature sensors.
106 106  
107 107  === Output discrete signals ===
... ... @@ -112,11 +112,31 @@
112 112  
113 113  [[image:1735054536275-447.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]]
114 114  
115 -(% class="box infomessage" %)
116 -(((
117 -A list of available **discrete output** assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]].
118 -)))
108 +The device supports the following assignments for discrete outputs:
119 119  
110 +* No output – output is not used.
111 +* Low SOC – a signal corresponding the low SOC of the battery;
112 +* High charging current – charging current is high;
113 +* Main contactor – state of the main contactor;
114 +* Charging – state of the charging contactor;
115 +* Allow charging – a signal for a charger to start charging;
116 +* Charging current present – the presence of the charging current;
117 +* Precharging – state of the precharging contactor;
118 +* Discharging – state of the discharging contactor;
119 +* Discharging current present – the presence of the discharging current;
120 +* Discharging (AUX) – state of the auxiliary discharging contactor;
121 +* Power down ACK – an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;
122 +* Charging/discharging - state of the charging/discharging contactor;
123 +* Heater – a command to turn on a heater;
124 +* Cooler – a command to turn on a cooler;
125 +* Balancing 1 – balancing the first series of cells;
126 +* Balancing 2 – balancing the second series of cells;
127 +* Ready to charge – the battery is ready to be charged;
128 +* Ready to discharge – the battery is ready to be discharged;
129 +* Power up – an indication of BMS power status;
130 +* General error – state of the configurable (general) error;
131 +* External 1 – a signal that activates by the remote request.
132 +
120 120  Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section:
121 121  
122 122  [[image:1735054654975-772.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]]
... ... @@ -129,10 +129,7 @@
129 129  
130 130  [[image:1735054694689-808.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="167" width="800"]]
131 131  
132 -(% class="box infomessage" %)
133 -(((
134 -A list of available **switch **assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]].
135 -)))
145 +The device supports the same switch assignments as discrete outputs (see [[Output discrete signals>>doc:||anchor="HOutputdiscretesignals"]]).
136 136  
137 137  Inversion flags for switches are configured in the “Signals → Power switches → Inversion” section:
138 138  
1750259757728-314.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -23.5 KB
Content
1750260739668-708.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -23.5 KB
Content