Changes for page 3.2 Inputs and outputs

Last modified by Admin on 2025/06/18 15:33

From version 18.3
edited by Admin
on 2025/06/18 15:31
Change comment: There is no comment for this version
To version 15.1
edited by Admin
on 2025/02/11 14:17
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -14,10 +14,7 @@
14 14  
15 15  [[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]]
16 16  
17 -(% class="box infomessage" %)
18 -(((
19 -A list of available **discrete input** assignments is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]].
20 -)))
17 +A list of available discrete input assignments is available in [[Battery controllers: signals and errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]].
21 21  
22 22  Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section:
23 23  
... ... @@ -98,10 +98,6 @@
98 98  
99 99  In this section:
100 100  
101 -* Type of cell temperature sensors – a type of temperature sensors connected to BMS Logic devices and used to measure cells temperature;
102 -* Unused cell temperature sensors – a bitfield to select unused temperature sensors on each BMS Logic;ры на каждом BMS Logic;
103 -* Type of temperature sensors 1 and 2 – тип температурных датчиков, подключенных к BMS Main 3.
104 -*
105 105  * Type – a type of temperature sensors.
106 106  
107 107  === Output discrete signals ===
... ... @@ -112,10 +112,7 @@
112 112  
113 113  [[image:1735054536275-447.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]]
114 114  
115 -(% class="box infomessage" %)
116 -(((
117 -A list of available **discrete output** assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]].
118 -)))
108 +A list of available discrete output assignments is available in [[Battery controllers: signals and errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]].
119 119  
120 120  Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section:
121 121  
... ... @@ -129,10 +129,7 @@
129 129  
130 130  [[image:1735054694689-808.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="167" width="800"]]
131 131  
132 -(% class="box infomessage" %)
133 -(((
134 -A list of available **switch **assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]].
135 -)))
122 +A list of available switch assignments is available in [[Battery controllers: signals and errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]].
136 136  
137 137  Inversion flags for switches are configured in the “Signals → Power switches → Inversion” section:
138 138  
1750259757728-314.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -23.5 KB
Content