Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/06/18 15:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 1 removed)
Details
- Page properties
-
- Content
-
... ... @@ -14,11 +14,30 @@ 14 14 15 15 [[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]] 16 16 17 -(% class="box infomessage" %) 18 -((( 19 -A list of available **discrete input** assignments is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]]. 20 -))) 17 +The device supports the following assignments for discrete inputs: 21 21 19 +* No input – input is not used; 20 +* Battery cover – a signal from the battery cover; 21 +* Charger connected – a signal indicating that charger is connected; 22 +* Power up/down request – a request to power down the device; 23 +* Inhibit charging – a command to open the charging contactor; 24 +* Inhibit discharging – a command to open the discharging contactor; 25 +* CH contactor feedback – a signal from charging contactor feedback loop; 26 +* DCH contactor feedback – a signal from discharging contactor feedback loop; 27 +* Insulation status – a signal from an insulation monitoring device; 28 +* Charge request – a request to close the charging contactor; 29 +* Precharge request – a request to close the precharging contactor; 30 +* Discharge request – a request to close the discharging contactor; 31 +* PCH contactor feedback – a signal from precharging contactor feedback loop; 32 +* CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop; 33 +* Main contactor feedback – a signal from main contactor feedback loop; 34 +* Interlock – a signal from interlock loop; 35 +* Fuse 1, Fuse 2, Fuse 3 – signals from fuses; 36 +* Circuit breaker status – status of protection disconnector; 37 +* Balancing request – a request to balance the cells; 38 +* Close Main contactor – a request to close the main contactor; 39 +* Close External 1 – a request to close the External 1 discrete output (if assigned). 40 + 22 22 Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section: 23 23 24 24 [[image:1735054242278-319.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="800"]] ... ... @@ -98,10 +98,6 @@ 98 98 99 99 In this section: 100 100 101 -* Type of cell temperature sensors – a type of temperature sensors connected to BMS Logic devices and used to measure cells temperature; 102 -* Unused cell temperature sensors – a bitfield to select unused temperature sensors on each BMS Logic;битовое поле для выбора неиспользуемых датчиков температуры на каждом BMS Logic; 103 -* Type of temperature sensors 1 and 2 – тип температурных датчиков, подключенных к BMS Main 3. 104 -* 105 105 * Type – a type of temperature sensors. 106 106 107 107 === Output discrete signals === ... ... @@ -112,11 +112,31 @@ 112 112 113 113 [[image:1735054536275-447.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]] 114 114 115 -(% class="box infomessage" %) 116 -((( 117 -A list of available **discrete output** assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 118 -))) 130 +The device supports the following assignments for discrete outputs: 119 119 132 +* No output – output is not used. 133 +* Low SOC – a signal corresponding the low SOC of the battery; 134 +* High charging current – charging current is high; 135 +* Main contactor – state of the main contactor; 136 +* Charging – state of the charging contactor; 137 +* Allow charging – a signal for a charger to start charging; 138 +* Charging current present – the presence of the charging current; 139 +* Precharging – state of the precharging contactor; 140 +* Discharging – state of the discharging contactor; 141 +* Discharging current present – the presence of the discharging current; 142 +* Discharging (AUX) – state of the auxiliary discharging contactor; 143 +* Power down ACK – an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request; 144 +* Charging/discharging - state of the charging/discharging contactor; 145 +* Heater – a command to turn on a heater; 146 +* Cooler – a command to turn on a cooler; 147 +* Balancing 1 – balancing the first series of cells; 148 +* Balancing 2 – balancing the second series of cells; 149 +* Ready to charge – the battery is ready to be charged; 150 +* Ready to discharge – the battery is ready to be discharged; 151 +* Power up – an indication of BMS power status; 152 +* General error – state of the configurable (general) error; 153 +* External 1 – a signal that activates by the remote request. 154 + 120 120 Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section: 121 121 122 122 [[image:1735054654975-772.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]] ... ... @@ -127,15 +127,12 @@ 127 127 128 128 Assignments of power switches are configured in the "Signals → Power switches → Assignments" section: 129 129 130 -[[image:1735054694689-808.png ||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="167" width="800"]]165 +[[image:1735054694689-808.png]] 131 131 132 -(% class="box infomessage" %) 133 -((( 134 -A list of available **switch **assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]]. 135 -))) 167 +The device supports the same switch assignments as discrete outputs. 136 136 137 137 Inversion flags for switches are configured in the “Signals → Power switches → Inversion” section: 138 138 139 -[[image:173 5054793459-953.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="149" width="800"]]171 +[[image:1733320685783-267.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="150" width="800"]] 140 140 141 141
- 1750259757728-314.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -23.5 KB - Content