15 15  [[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]]
16 16  
17 -(% class="box infomessage" %)
18 -(((
19 -A list of available **discrete input** assignments is available in [[Input signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInputsignals"]].
20 -)))
17 +A list of available discrete input assignments is available in
21 21  
22 22  Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section:
23 23  
... ... @@ -108,11 +108,31 @@
108 108  
109 109  [[image:1735054536275-447.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]]
110 110  
111 -(% class="box infomessage" %)
112 -(((
113 -A list of available **discrete output** assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]].
114 -)))
108 +The device supports the following assignments for discrete outputs:
115 115  
110 +* No output – output is not used.
111 +* Low SOC – a signal corresponding the low SOC of the battery;
112 +* High charging current – charging current is high;
113 +* Main contactor – state of the main contactor;
114 +* Charging – state of the charging contactor;
115 +* Allow charging – a signal for a charger to start charging;
116 +* Charging current present – the presence of the charging current;
117 +* Precharging – state of the precharging contactor;
118 +* Discharging – state of the discharging contactor;
119 +* Discharging current present – the presence of the discharging current;
120 +* Discharging (AUX) – state of the auxiliary discharging contactor;
121 +* Power down ACK – an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;
122 +* Charging/discharging - state of the charging/discharging contactor;
123 +* Heater – a command to turn on a heater;
124 +* Cooler – a command to turn on a cooler;
125 +* Balancing 1 – balancing the first series of cells;
126 +* Balancing 2 – balancing the second series of cells;
127 +* Ready to charge – the battery is ready to be charged;
128 +* Ready to discharge – the battery is ready to be discharged;
129 +* Power up – an indication of BMS power status;
130 +* General error – state of the configurable (general) error;
131 +* External 1 – a signal that activates by the remote request.
132 +
116 116  Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section:
117 117  
118 118  [[image:1735054654975-772.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]]
... ... @@ -125,10 +125,7 @@
125 125  
126 126  [[image:1735054694689-808.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="167" width="800"]]
127 127  
128 -(% class="box infomessage" %)
129 -(((
130 -A list of available **switch **assignments is available in [[Internal signals>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals and errors.WebHome||anchor="HInternalsignals"]].
131 -)))
145 +The device supports the same switch assignments as discrete outputs (see [[Output discrete signals>>doc:||anchor="HOutputdiscretesignals"]]).
132 132  
133 133  Inversion flags for switches are configured in the “Signals → Power switches → Inversion” section:
134 134  
1750259757728-314.png
Author
... ... @@ -1,1 +1,0 @@
1 -XWiki.admin
Size
... ... @@ -1,1 +1,0 @@
1 -23.5 KB
Content