Changes for page 3.2 Inputs and outputs

Last modified by Admin on 2025/06/18 15:33

From version 12.3
edited by Admin
on 2025/02/11 13:03
Change comment: There is no comment for this version
To version 12.2
edited by Admin
on 2025/02/11 13:02
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -14,7 +14,7 @@
14 14  
15 15  [[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]]
16 16  
17 -A list of available discrete input assignments is available in [[Battery controllers: signals, states and errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals, states and errors.WebHome||anchor="HInputsignals"]].
17 +A list of available discrete input assignments is available in
18 18  
19 19  Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section:
20 20  
... ... @@ -105,8 +105,31 @@
105 105  
106 106  [[image:1735054536275-447.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]]
107 107  
108 -A list of available discrete input assignments is available in [[Battery controllers: signals, states and errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals, states and errors.WebHome||anchor="HInputsignals"]].
108 +The device supports the following assignments for discrete outputs:
109 109  
110 +* No output – output is not used.
111 +* Low SOC – a signal corresponding the low SOC of the battery;
112 +* High charging current – charging current is high;
113 +* Main contactor – state of the main contactor;
114 +* Charging – state of the charging contactor;
115 +* Allow charging – a signal for a charger to start charging;
116 +* Charging current present – the presence of the charging current;
117 +* Precharging – state of the precharging contactor;
118 +* Discharging – state of the discharging contactor;
119 +* Discharging current present – the presence of the discharging current;
120 +* Discharging (AUX) – state of the auxiliary discharging contactor;
121 +* Power down ACK – an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;
122 +* Charging/discharging - state of the charging/discharging contactor;
123 +* Heater – a command to turn on a heater;
124 +* Cooler – a command to turn on a cooler;
125 +* Balancing 1 – balancing the first series of cells;
126 +* Balancing 2 – balancing the second series of cells;
127 +* Ready to charge – the battery is ready to be charged;
128 +* Ready to discharge – the battery is ready to be discharged;
129 +* Power up – an indication of BMS power status;
130 +* General error – state of the configurable (general) error;
131 +* External 1 – a signal that activates by the remote request.
132 +
110 110  Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section:
111 111  
112 112  [[image:1735054654975-772.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]]