Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/06/18 15:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -14,7 +14,7 @@ 14 14 15 15 [[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]] 16 16 17 -A list of available discrete input assignments is available in [[Battery controllers: signals, states and errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals, states and errors.WebHome||anchor="HInputsignals"]].17 +A list of available discrete input assignments is available in 18 18 19 19 Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section: 20 20 ... ... @@ -105,8 +105,31 @@ 105 105 106 106 [[image:1735054536275-447.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]] 107 107 108 - A list of available discreteinputassignmentsis available in [[Batterycontrollers: signals,statesand errors>>doc:Battery managementystems.Additionalinformation.1\.Batterycontrollers\: signals, statesand errors.WebHome||anchor="HInputsignals"]].108 +The device supports the following assignments for discrete outputs: 109 109 110 +* No output – output is not used. 111 +* Low SOC – a signal corresponding the low SOC of the battery; 112 +* High charging current – charging current is high; 113 +* Main contactor – state of the main contactor; 114 +* Charging – state of the charging contactor; 115 +* Allow charging – a signal for a charger to start charging; 116 +* Charging current present – the presence of the charging current; 117 +* Precharging – state of the precharging contactor; 118 +* Discharging – state of the discharging contactor; 119 +* Discharging current present – the presence of the discharging current; 120 +* Discharging (AUX) – state of the auxiliary discharging contactor; 121 +* Power down ACK – an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request; 122 +* Charging/discharging - state of the charging/discharging contactor; 123 +* Heater – a command to turn on a heater; 124 +* Cooler – a command to turn on a cooler; 125 +* Balancing 1 – balancing the first series of cells; 126 +* Balancing 2 – balancing the second series of cells; 127 +* Ready to charge – the battery is ready to be charged; 128 +* Ready to discharge – the battery is ready to be discharged; 129 +* Power up – an indication of BMS power status; 130 +* General error – state of the configurable (general) error; 131 +* External 1 – a signal that activates by the remote request. 132 + 110 110 Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section: 111 111 112 112 [[image:1735054654975-772.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]]