Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/06/18 15:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
Details
- Page properties
-
- Content
-
... ... @@ -14,8 +14,30 @@ 14 14 15 15 [[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]] 16 16 17 - A list of available discreteinputassignmentsis available in [[Batterycontrollers: signals,statesand errors>>doc:Battery managementystems.Additionalinformation.1\.Batterycontrollers\: signals, statesand errors.WebHome||anchor="HInputsignals"]].17 +The device supports the following assignments for discrete inputs: 18 18 19 +* No input – input is not used; 20 +* Battery cover – a signal from the battery cover; 21 +* Charger connected – a signal indicating that charger is connected; 22 +* Power up/down request – a request to power down the device; 23 +* Inhibit charging – a command to open the charging contactor; 24 +* Inhibit discharging – a command to open the discharging contactor; 25 +* CH contactor feedback – a signal from charging contactor feedback loop; 26 +* DCH contactor feedback – a signal from discharging contactor feedback loop; 27 +* Insulation status – a signal from an insulation monitoring device; 28 +* Charge request – a request to close the charging contactor; 29 +* Precharge request – a request to close the precharging contactor; 30 +* Discharge request – a request to close the discharging contactor; 31 +* PCH contactor feedback – a signal from precharging contactor feedback loop; 32 +* CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop; 33 +* Main contactor feedback – a signal from main contactor feedback loop; 34 +* Interlock – a signal from interlock loop; 35 +* Fuse 1, Fuse 2, Fuse 3 – signals from fuses; 36 +* Circuit breaker status – status of protection disconnector; 37 +* Balancing request – a request to balance the cells; 38 +* Close Main contactor – a request to close the main contactor; 39 +* Close External 1 – a request to close the External 1 discrete output (if assigned). 40 + 19 19 Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section: 20 20 21 21 [[image:1735054242278-319.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="800"]] ... ... @@ -105,8 +105,31 @@ 105 105 106 106 [[image:1735054536275-447.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]] 107 107 108 - A list of available discreteinputassignmentsis available in [[Batterycontrollers: signals,statesand errors>>doc:Battery managementystems.Additionalinformation.1\.Batterycontrollers\: signals, statesand errors.WebHome||anchor="HInputsignals"]].130 +The device supports the following assignments for discrete outputs: 109 109 132 +* No output – output is not used. 133 +* Low SOC – a signal corresponding the low SOC of the battery; 134 +* High charging current – charging current is high; 135 +* Main contactor – state of the main contactor; 136 +* Charging – state of the charging contactor; 137 +* Allow charging – a signal for a charger to start charging; 138 +* Charging current present – the presence of the charging current; 139 +* Precharging – state of the precharging contactor; 140 +* Discharging – state of the discharging contactor; 141 +* Discharging current present – the presence of the discharging current; 142 +* Discharging (AUX) – state of the auxiliary discharging contactor; 143 +* Power down ACK – an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request; 144 +* Charging/discharging - state of the charging/discharging contactor; 145 +* Heater – a command to turn on a heater; 146 +* Cooler – a command to turn on a cooler; 147 +* Balancing 1 – balancing the first series of cells; 148 +* Balancing 2 – balancing the second series of cells; 149 +* Ready to charge – the battery is ready to be charged; 150 +* Ready to discharge – the battery is ready to be discharged; 151 +* Power up – an indication of BMS power status; 152 +* General error – state of the configurable (general) error; 153 +* External 1 – a signal that activates by the remote request. 154 + 110 110 Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section: 111 111 112 112 [[image:1735054654975-772.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]]