Changes for page 3.2 Inputs and outputs

Last modified by Admin on 2025/06/18 15:33

From version 12.3
edited by Admin
on 2025/02/11 13:03
Change comment: There is no comment for this version
To version 11.2
edited by Admin
on 2024/12/24 15:39
Change comment: There is no comment for this version

Summary

Details

Page properties
Content
... ... @@ -14,8 +14,30 @@
14 14  
15 15  [[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]]
16 16  
17 -A list of available discrete input assignments is available in [[Battery controllers: signals, states and errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals, states and errors.WebHome||anchor="HInputsignals"]].
17 +The device supports the following assignments for discrete inputs:
18 18  
19 +* No input – input is not used;
20 +* Battery cover – a signal from the battery cover;
21 +* Charger connected – a signal indicating that charger is connected;
22 +* Power up/down request – a request to power down the device;
23 +* Inhibit charging – a command to open the charging contactor;
24 +* Inhibit discharging – a command to open the discharging contactor;
25 +* CH contactor feedback – a signal from charging contactor feedback loop;
26 +* DCH contactor feedback – a signal from discharging contactor feedback loop;
27 +* Insulation status – a signal from an insulation monitoring device;
28 +* Charge request – a request to close the charging contactor;
29 +* Precharge request – a request to close the precharging contactor;
30 +* Discharge request – a request to close the discharging contactor;
31 +* PCH contactor feedback – a signal from precharging contactor feedback loop;
32 +* CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop;
33 +* Main contactor feedback – a signal from main contactor feedback loop;
34 +* Interlock – a signal from interlock loop;
35 +* Fuse 1, Fuse 2, Fuse 3 – signals from fuses;
36 +* Circuit breaker status – status of protection disconnector;
37 +* Balancing request – a request to balance the cells;
38 +* Close Main contactor – a request to close the main contactor;
39 +* Close External 1 – a request to close the External 1 discrete output (if assigned).
40 +
19 19  Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section:
20 20  
21 21  [[image:1735054242278-319.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="800"]]
... ... @@ -105,8 +105,31 @@
105 105  
106 106  [[image:1735054536275-447.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]]
107 107  
108 -A list of available discrete input assignments is available in [[Battery controllers: signals, states and errors>>doc:Battery management systems.Additional information.1\. Battery controllers\: signals, states and errors.WebHome||anchor="HInputsignals"]].
130 +The device supports the following assignments for discrete outputs:
109 109  
132 +* No output – output is not used.
133 +* Low SOC – a signal corresponding the low SOC of the battery;
134 +* High charging current – charging current is high;
135 +* Main contactor – state of the main contactor;
136 +* Charging – state of the charging contactor;
137 +* Allow charging – a signal for a charger to start charging;
138 +* Charging current present – the presence of the charging current;
139 +* Precharging – state of the precharging contactor;
140 +* Discharging – state of the discharging contactor;
141 +* Discharging current present – the presence of the discharging current;
142 +* Discharging (AUX) – state of the auxiliary discharging contactor;
143 +* Power down ACK – an acknowledgement of BMS power down. Acknowledgement is outputted when the charge and discharge contactors have been opened on power down request;
144 +* Charging/discharging - state of the charging/discharging contactor;
145 +* Heater – a command to turn on a heater;
146 +* Cooler – a command to turn on a cooler;
147 +* Balancing 1 – balancing the first series of cells;
148 +* Balancing 2 – balancing the second series of cells;
149 +* Ready to charge – the battery is ready to be charged;
150 +* Ready to discharge – the battery is ready to be discharged;
151 +* Power up – an indication of BMS power status;
152 +* General error – state of the configurable (general) error;
153 +* External 1 – a signal that activates by the remote request.
154 +
110 110  Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section:
111 111  
112 112  [[image:1735054654975-772.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]]
... ... @@ -123,6 +123,5 @@
123 123  
124 124  Inversion flags for switches are configured in the “Signals → Power switches → Inversion” section:
125 125  
126 -[[image:1735054793459-953.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="149" width="800"]]
127 127  
128 128