Changes for page 3.2 Inputs and outputs
Last modified by Admin on 2025/06/18 15:33
Summary
-
Page properties (1 modified, 0 added, 0 removed)
-
Attachments (0 modified, 0 added, 5 removed)
Details
- Page properties
-
- Content
-
... ... @@ -14,8 +14,30 @@ 14 14 15 15 [[image:1735053944168-184.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="236" width="800"]] 16 16 17 - Alist of availablediscrete inputassignmentsisavailable in17 +The device supports the following assignments for discrete inputs: 18 18 19 +* No input – input is not used; 20 +* Battery cover – a signal from the battery cover; 21 +* Charger connected – a signal indicating that charger is connected; 22 +* Power up/down request – a request to power down the device; 23 +* Inhibit charging – a command to open the charging contactor; 24 +* Inhibit discharging – a command to open the discharging contactor; 25 +* CH contactor feedback – a signal from charging contactor feedback loop; 26 +* DCH contactor feedback – a signal from discharging contactor feedback loop; 27 +* Insulation status – a signal from an insulation monitoring device; 28 +* Charge request – a request to close the charging contactor; 29 +* Precharge request – a request to close the precharging contactor; 30 +* Discharge request – a request to close the discharging contactor; 31 +* PCH contactor feedback – a signal from precharging contactor feedback loop; 32 +* CH/DCH contactor feedback – a signal from charging/discharging contactor feedback loop; 33 +* Main contactor feedback – a signal from main contactor feedback loop; 34 +* Interlock – a signal from interlock loop; 35 +* Fuse 1, Fuse 2, Fuse 3 – signals from fuses; 36 +* Circuit breaker status – status of protection disconnector; 37 +* Balancing request – a request to balance the cells; 38 +* Close Main contactor – a request to close the main contactor; 39 +* Close External 1 – a request to close the External 1 discrete output (if assigned). 40 + 19 19 Inversion flags for discrete inputs are configured in the "Signals → Input discrete signals → Inversion" section: 20 20 21 21 [[image:1735054242278-319.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="207" width="800"]] ... ... @@ -40,7 +40,7 @@ 40 40 41 41 Current sensor settings are configured in the "Signals → Current sensor" section: 42 42 43 -[[image:173 5054422436-925.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="391" width="800"]]65 +[[image:1733320685773-566.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="361" width="800"]] 44 44 45 45 The device supports the following current sensor settings: 46 46 ... ... @@ -103,7 +103,7 @@ 103 103 104 104 Assignments of discrete outputs are configured in the "Signals → Output discrete signals → Assignments" section: 105 105 106 -[[image:173 5054536275-447.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]]128 +[[image:1733320685778-896.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="148" width="800"]] 107 107 108 108 The device supports the following assignments for discrete outputs: 109 109 ... ... @@ -126,13 +126,12 @@ 126 126 * Balancing 2 – balancing the second series of cells; 127 127 * Ready to charge – the battery is ready to be charged; 128 128 * Ready to discharge – the battery is ready to be discharged; 129 -* Power up – an indication of BMS power status; 130 -* General error – state of the configurable (general) error; 131 -* External 1 – a signal that activates by the remote request. 151 +* Power up – an indication of BMS power status. 152 +* General error – state of the configurable (general) error. 132 132 133 133 Inversion flags for discrete outputs are configured in the "Signals → Output discrete signals → Inversion" section: 134 134 135 -[[image:173 5054654975-772.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="124" width="800"]]156 +[[image:1733320685780-193.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="127" width="800"]] 136 136 137 137 === Power switches === 138 138 ... ... @@ -140,12 +140,12 @@ 140 140 141 141 Assignments of power switches are configured in the "Signals → Power switches → Assignments" section: 142 142 143 -[[image:173 5054694689-808.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="167" width="800"]]164 +[[image:1733320685782-487.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="168" width="800"]] 144 144 145 -The device supports the same switch assignments as discrete outputs (see [[Output discrete signals>>doc:||anchor="HOutputdiscretesignals"]]).166 +The device supports the same switch assignments as discrete outputs. 146 146 147 147 Inversion flags for switches are configured in the “Signals → Power switches → Inversion” section: 148 148 149 -[[image:173 5054793459-953.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="149" width="800"]]170 +[[image:1733320685783-267.png||data-xwiki-image-style-alignment="center" data-xwiki-image-style-border="true" height="150" width="800"]] 150 150 151 151
- 1735054422436-925.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -83.9 KB - Content
- 1735054536275-447.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -28.7 KB - Content
- 1735054654975-772.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -20.3 KB - Content
- 1735054694689-808.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -33.5 KB - Content
- 1735054793459-953.png
-
- Author
-
... ... @@ -1,1 +1,0 @@ 1 -XWiki.admin - Size
-
... ... @@ -1,1 +1,0 @@ 1 -23.3 KB - Content